User Set Parameters
Parameter | Description |
Frame Rate (in Hz) | Specifies the internal trigger frame rate for free run mode, in Hz. |
| Possible values range from 0.1 to 64.0 Hz for Genie M640 in full scan mode. |
| (Note: the Sapera SDK specifies the frame rate in milliHertz). |
| The maximum frame rate increases by using binning (see below) or partial scan (see "Partial |
| |
Gain (in dB) | Specifies the sensor analog Gain factor, in dB. Possible values range from |
| |
| Controls" on page 36. |
Black level (in 1/16 DN) | Specifies the sensor black level, in 1/16 DN (digital number, which is the value assigned to a |
| pixel in a digital image). Possible values range from |
Binning Horizontal | Enables or disables horizontal binning. Possible values are Disabled or 2 pixels. When set to 2 |
| pixels, the image buffer width parameter is automatically adjusted. For more information, see |
| "Binning" on page 41. |
Binning Vertical | Enables or disables the vertical binning. Possible values are Disabled or 2 lines. When set to 2 |
| lines, the image buffer height parameter is automatically adjusted. The maximum frame rate |
| also increases. |
Test Image Selector | Specifies the test image. Possible values are: |
| Off |
| Grey Horizontal Ramp |
| Grey Vertical Ramp |
| Grey Diagonal Ramp Moving |
| Purity |
| For more information, see "Internal Image Test Patterns" on page 62. |
Exposure Control | Click Setting to open the Exposure Control dialog. For more information, see "Exposure |
| Controls" on page 43. |
Genie Monochrome | Operational Reference • 35 |