Output Control via Sapera LT or GenICam Applications

Sapera

Genie Sapera parameters for Strobe and General Outputs. See "Accessing Features with Sapera++ LT" on page 68.

OutputSelectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2, Pulse On:

Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout = 6, Pulse On: End

of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input 1 = 9, Pulse On: Input 2 = 10} PulseDelayOutput_x = Delay in µs to assert pulse output

PulseDurationOutput_x = Pulse duration in µs PolarityOutput_x = {Active Close = 0, Active Open = 1}

GenICam features for Strobe and General Outputs:

OutputLineSelector = Index to select output line {output 1 = 0, output 2 = 1}

OutputLineMode = {SoftwareDriven = 0, EventDriven = 1}

OutputLineEventSource = Event generating output line pulse {StartOfTrigger=0,

StartOfExposure=1, EndOfExposure=2, StartOfReadout=3, EndOfReadout=4,

EndOfAcquisition=5, EventOnInputLine1=6, EventOnInputLine2=7, OverTrigger=8,

OutputLinePulsePolarity = State of output opto-coupler {Active Close = 0, Active Open = 1}

OutputLinePulseDelay = Delay in µs to assert pulse output (range 0 to 64k)

OutputLinePulseDuration = Pulse duration in µs (range 0 to 64k)

OutputLineValue = static output state {Open = 0, Close = 1}

Genie Processing Features

The Genie monochrome series of cameras support a number of functions to enhance acquisitions or perform real time processing. Functions can be combined to solve specific imaging situations. The user can enable and evaluate each operation by using CamExpert.

Lookup Table (LUT)

The Genie camera includes a user programmable LUT as a component of its embedded processing features. The LUT is used for operations such as gamma adjustments, invert and threshold processes. CamExpert has a number of built in LUT operations for the user to explore (see "CamExpert LUT Controls" on page 87).

For monochrome sensors, the LUT table is a single 8-bit or 10-bit LUT (8/10-bit in, 8/10-bit out) as illustrated in the following figure. Pixel data when read out of the sensor is passed through the LUT memory array, where the new programmed pixel value is then passed to the Genie output circuit. The LUT data table is stored along with other parameters with the user configuration function (see "Power-up Configuration" on page 32).

56 Operational Reference

Genie Monochrome Series-GigE Vision Camera

Page 58
Image 58
Faber M1024, M640, M1600 Genie Processing Features, Output Control via Sapera LT or GenICam Applications, Lookup Table LUT