Faber M1600, M640, M1024, M1400 user manual Genie Signal Electrical Details, External Inputs

Models: M1600 M1400 M640 M1024

1 127
Download 127 pages 55.97 Kb
Page 93
Image 93

Genie Signal Electrical Details

Power Supply (pin 2): +12V DC nominal. Operating tolerance +10% to –10%.

Over voltage and reverse voltage protection circuit built in. The protection circuit is reset by shutting down or disconnecting the power supply.

The 12-pin Hirose male connector shell and cable shield should connect to the supply earth ground to improve EMI shielding.

External Inputs

Opto-coupled (2V to 12V, 2mA minimum) with internal current limit.

RS422 or TTL signal type.

Used as trigger or integration control.

External signal polarity selected via configuration parameter.

User programmable debounce time from 1 to 255µs.

See "Input Controls via Sapera LT or GenICam Applications" on page 50.

V+

Event Buffer

Signal driver

example

74HC244

example

TTL externalGenie device

680

IN+

.01µf

IN-

Fairchild

Hirose 12HMHA281R connector

3.3V

4.7K

Trigger

Debounce

IN

External Input Detail with an Example Signal Driver

The opto-coupler is typically a Fairchild HMHA281 with the following characteristics.

Input Electrical Parameter Description

Value

Voltage threshold to turn OFF

0.8 V

Voltage threshold to turn ON

2 V

Minimum input current to turn ON

2 mA

Maximum input current

50 mA

Minimum input pulse width to turn ON

30 us

Maximum input voltage

13 V

 

 