Power-up Control via Sapera LT or GenICam Applications

Sapera

Genie Sapera parameters for Power-up Configuration:

Power-upConfig= {Factory Default = 0, Camera Configuration 1 = 1}

SaveCameraConfigurationSelector = {Camera Configuration 1 = 1} SaveCameraConfiguration = Write to save selected camera configuration LoadCameraConfigurationSelector = {Factory Default = 0, Camera Configuration 1 = 1} LoadCameraConfiguration = Write to load selected camera configuration

In CamExpert, these parameters are available in the “Camera Information” tab, under the “Power- up Configuration” dialog box.

See "Accessing Features with Sapera++ LT" on page 68.

GenICam features for Power-up Configuration:

UserSetSelector = {Factory = 0, UserSet1 = 1}

UserSetLoad = Loads the User Set specified by UserSetSelector to the camera and makes it active

UserSetSave = Saves the User Set specified by UserSetSelector to the camera UserSetDefaultSelector = Selects the feature User Set to load at camera reset

Sapera Supported Features List

The Genie features and its currently set values can be read by a Sapera application. The Sapera tool CamExpert is an example of an application that reads and writes Genie parameters to control its operation.

The following tables group the Genie features by their feature type—STRING, ENUM, INT32, and BOOL. Features may be read only (RO), read/write (RW), or write only (WO).

Accessing Features with Sapera++ LT

When working with Genie features, the SapAcqDevice class provides functions for accessing features from devices such as a GigE-Vision camera. The class also contains functions for sending commands and registering events to devices.

SapAcqDevice::GetFeatureInfo returns information on a feature associated with a specified name or index.

SapAcqDevice::SetFeatureValue writes a new value for a feature.

All information about the feature is stored in a SapFeature class object.

Refer to the Sapera++ LT Programmer's manual (OC-SAPM-SPPP0).