Manuals
/
Faber
/
Photography
/
Security Camera
Faber
M1400, M640, M1600, M1024
user manual
Technical Specifications, Mechanical Specifications
Models:
M1600
M1400
M640
M1024
1
91
127
127
Download
127 pages
55.97 Kb
88
89
90
91
92
93
94
95
Troubleshooting
Specs
Install
Device IP Error
Power-up Configuration
Streaming Video grab Issues
Reset Mode
Access Via CamExpert
Connectors
Procedure
Page 91
Image 91
Technical Specifications
Mechanical Specifications
The figure below defines the Genie family mechanical specifications. Additional notes follow.
Genie Monochrome
Series-GigE
Vision Camera
Technical Specifications
•
89
Page 90
Page 92
Page 91
Image 91
Page 90
Page 92
Contents
Genie Framework M640 M1024 M1400 M1600
Genie Monochrome Series
CA-GENM-MUM00
Contents
Ynchronization T Iming
Sapera Camexpert Guide
Dalsa Contact Information
Description
Genie Monochrome Series Overview
Genie Application Advantages
Fps Product Number
Camera Sensor Size Resolution
Genie Cables & Accessories sold separately Product number
Product Part Numbers
Camera Performance Specifications
RoHS
Supported Industry Standards
Genie Sensor Overview
Certifications
Item / Feature Specification
Genie M640-1/2 Specifications
Genie M640-1/3 Specifications
Genie M1024 Specifications
ICX267AL
Genie M1400 Specifications
Genie M1600 Specifications
Sapera LT Library with optional Processing
Application Development Overview
GenICam Environment
Page
GigE Network Adapter Guideline
Installing the Genie Camera
Supported Network Configurations
Using Genie with Ethernet Switches
Using Genie with a Vlan Ethernet Switch
Installation Overview & Preparations
Network and Computer Overview
Installation Overview
Sapera LT Library Installation
Procedure
Genie CD Package Installation
GigE Server Verification
Connect the Genie Camera
Connectors
LED State Definition
Status LED Codes
Typical LED States on Power Up
Genie IP Configuration Sequence
GigE Server Status
Increasing Adapter Buffers and Jumbo Frames
Optimizing the Network Adapter used with Genie
Receive Descriptors
Select NIC Advanced Configuration Properties
Jumbo Frames
Running the Network Configuration Tool
Updating Genie Firmware
Page
Quick Test with CamExpert
About the User-Defined Camera Name
Operational Reference
Access Via CamExpert
Camera and Sensor Information
Parameter Description
Power-up Configuration
Read Only Parameters
User Set Parameters
Camera Information via Sapera LT or GenICam Applications
Sapera
Sensor Parameters Controls Via CamExpert
Sensor Controls
Controls on
Gain and Black Level Controls
Partial Scan vertical cropping
Partial Scan-Window ROI
Vertical Lines M640 M1024 M1400 Acquired
Window ROI
Partial Scan horizontal cropping
Window ROI Control via Sapera LT or GenICam Applications
CamExpert Image Buffer and ROI Parameters
Binning
Binning Control via Sapera LT or GenICam Applications
Trigger Modes
Free-running Programmable Exposure
Exposure Controls
External Trigger Programmable Exposure
Exposure Controls via Sapera LT or GenICam Applications
External Trigger Level-controlled Exposure
Synchronization Timing
Synchronous Mode
Synchronization Mode via Sapera LT or GenICam Applications
Reset Mode
Parameter Description
CamExpert I/O Controls Dialog
General Inputs Settings Via CamExpert
External Input Signal Opto-coupler & Debounce Circuit
General Inputs
TriggerSelector = not used
Input Controls via Sapera LT or GenICam Applications
Strobe and General Outputs
General Outputs Settings via CamExpert
Strobe On Start of Exposure Event Mode
Open and Close Output Settings
Pulse On Invalid Trigger Event Mode
Pulse On Valid Trigger Event Mode
Pulse On End of Readout Event Mode
Pulse On Start of Readout Event Mode
Pulse On Input 1 or Input 2 Event Modes
Pulse On End of Acquisition Event Mode
Output Control via Sapera LT or GenICam Applications
Genie Processing Features
Lookup Table LUT
Sapera++ classes used
LUT Control via Sapera LT or GenICam Applications
Flat Field Image Shading Correction
Flat Field Correction Calibration Procedure
CamExpert Flat Field Calibration Menu
Using Flat Field Correction
Horizontal
Image Flip
Vertical
Genie test patterns are
Internal Image Test Patterns
Test Image Select via Sapera LT or GenICam Applications
Events
Sapera Callbacks
Transfer Event Name Description
Event Selection via GenICam Applications
CamExpert GigE Vision Parameters
Network Controls & GigE Vision Parameters
Network Controls via Sapera LT or GenICam Applications
ROI
Genie Power-up Configuration
Power-up Control via Sapera LT or GenICam Applications
Sapera Supported Features List
Accessing Features with Sapera++ LT
Feature Name Access Type Values
Feature Type String
Feature Type Enum
Feature Name Access Type Value
LUTFormat
Feature Name Access Type Exponent Sample Value
Feature Type INT32
Feature Interdependence Diagrams
Feature Type Bool
Trigger Enable False
Trigger Enable True
Vertical Binning
Output Selector
Horizontal Binning
Pixel Format
Network Configuration Mode
Page
Network Tools
IP Configuration Mode Details
Link-Local Address LLA
Persistent IP
Dhcp Dynamic Host Configuration Protocol
Quick Genie Network Configuration
Network Configuration Tool
System Information and Configuration
NIC IP and Network Imaging Driver Assignment
Network Card Information and Configuration
To recover a Genie
Recovering a Camera with an Unknown Persistent IP
Sapera GigE Server Details
Status Window Description
Creating a Status Report
Sapera CamExpert Guide
Using CamExpert with Genie Monochrome Cameras
CamExpert Panes
Software trigger button
CamExpert LUT Controls
Bit Invert LUT
Mechanical Specifications
Technical Specifications
Pin Hirose Connector Signal Details
Connectors
Pin Direction Genie Signal see details below
External Inputs
Genie Signal Electrical Details
Input Electrical Parameter Description Value
Network Connection Network Activity
RJ45 LAN Ethernet Connector Details
External Outputs
Output Electrical Parameter Description Value
Light Sources
Camera Status LED
Optical Considerations
Illumination
Primary Points in a Lens System
Magnification and Resolution
Filters
Lens Modeling
Electrostatic Discharge and the CCD Sensor
Sensor Handling Instructions
Protecting Against Dust, Oil and Scratches
Environment
Cleaning the Sensor Window
Ruggedized RJ45 Ethernet Cables
Computer Requirements for Genie Cameras
Ethernet Switch Requirements
Host PC System
Ethernet to Fiber-Optic Interface Requirements
EC & FCC Declaration of Conformity
Problem Type Summary
Troubleshooting
Overview
Device Available but with Operational Issues
Device IP Error
Device Not Available
GigE Server Warning Example 1a IP error with multiple NICs
Installation Issues and Functional Problems
GigE Server Warning Example 1b IP error with multiple NICs
GigE Server Warning Example 3 Filter Driver CorSnid Disabled
GigE Server Warning Example 2 Subnet Mask or IP error
Firmware Updates
Device Available with Operational Issues
Streaming Error No Acquisition with a Timeout Message
Power Failure During a Firmware Update-Now What?
Disabling Windows Firewall
Turning Windows Firewall Off
Cabling and IP Configuration Issues
Test a Genie Using Internal Test Patterns
Streaming Video grab Issues
Grab has Random Bad Data or Noise
Grab Remains Black
Grab has Random Bad Data or Noise Case
Laptop Computer Networking Issues
Problems when Changing the Laptop NIC
Configuration Recommendations with Laptops
Multiple Camera Issues
Ethernet Switch Issues
Problems with Disconnecting NICs
No camera exposure when expected
Camera Exposure Issues
VPN Driver Interference
Verifying Network Parameters
Troubleshooting Genie Monochrome Series-GigE Vision Camera
Genie Sales Information
Dalsa Contact Information
International/Canada
Genie Technical Support
Glossary of Terms
Acquiring an image frame
SAT
Glossary of Terms Genie Monochrome Series-GigE Vision Camera
Genie Monochrome Series-GigE Vision Camera Index
Index
Index Genie Monochrome Series-GigE Vision Camera
Genie Monochrome Series-GigE Vision Camera Index
Top
Page
Image
Contents