Genie Power-up Configuration

On power up the Genie camera initializes to a factory default state which sets the camera with neutral parameters and in free run mode. The default state ensures that the camera is ready for acquisition. Genie also provides storage for one user-defined state. This user state allows quick camera configuration for a known repeatable imaging system. The following table describes the camera parameters stored in the user state. See "Power-up Configuration" on page 32 for information on saving the user state with CamExpert.

Parameter

Description

ROI

Region of interest used to crop the image

Pixel Format

Defines the pixel format (MONO8)

 

 

Frame Rate

Defines the frame rate for free run mode.

Exposure mode

Defines the exposure mode (Programmable or Pulse Controlled)

Exposure duration

Defines the exposure duration for Programmable mode

Exposure synchronization

Synchronous or Reset synchronization mode

 

 

Gain

Defines the sensor analog Gain factor.

Black Level

Defines the sensor analog Black level factor.

Binning

Horizontal and vertical binning factor

Flip

Horizontal flip: Off or On

Image source

Defines the image source as the sensor or one of the stored image patterns.

 

 

Trigger enable

Free-running or triggered

Trigger source

Selects the trigger input (input pin or software)

Trigger delay

Defines the delay from input trigger to exposure start.

GPI settings

Defines the operational mode of the general input pins.

 

 

GPO settings

Defines the operational mode of the general output pins

LUT

Lookup Table function On or Off plus the LUT data.

Flat Field Correction

FFC function On or Off plus the offset/gain data.

 

 