Faber M1024, M640, M1600 Event Selection via GenICam Applications, Transfer Event Name Description

Models: M1600 M1400 M640 M1024

1 127
Download 127 pages 55.97 Kb
Page 66
Image 66

Acquisition Device Event Name

Description

(case sensitive strings)

 

Start of Trigger

Trigger is valid based on the programmed trigger parameters

Start of Exposure

Exposure has started

 

 

End of Exposure

Exposure is complete

Feature Value Changed

Parameter value is changed

Feature Info Changed

Configuration parameter is changed

Invalid Trigger

Trigger event (software or external) was invalid

 

 

Input Event 0

External Input # 1 has received a valid signal

Input Event 1

External Input # 2 has received a valid signal

Output Event 0

External Output # 1 has changed state

Output Event 1

External Output # 2 has changed state

Transfer Event Name

Description

End of frame transfer

Video frame transferred to host buffer

Event Selection via GenICam Applications

GenICam features for Events:

EventSelector = {AcquisitionTrigger = 2, ExposureStart = 3, ExposureEnd = 4}

EventNotification = {Off = 0, GigEVisionEvent = 1}

64 Operational Reference

Genie Monochrome Series-GigE Vision Camera

Page 66
Image 66
Faber M1024, M640, M1600, M1400 user manual Event Selection via GenICam Applications, Transfer Event Name Description