White Rodgers 50a55-286 Typical System Wiring Table, 50A55, Terminal, System Component, Type

Models: 50a55-286

1 8
Download 8 pages 51.2 Kb
Page 5
Image 5
TYPICAL SYSTEM WIRING TABLE

TYPICAL SYSTEM WIRING TABLE

50A55

TERMINAL

SYSTEM COMPONENT

TERMINAL

TYPE

CONNECTION

W

 

low voltage thermostat W terminal (or equivalent)

G

Terminal

low voltage thermostat G terminal (or equivalent)

R

block with

low voltage thermostat R terminal (or equivalent)

Y

captive

low voltage thermostat Y terminal (or equivalent)

 

screws

(2nd wire from Y terminal goes to 24 VAC HOT side of

 

 

compressor contactor coil)

C

 

24 VAC COMMON side of compressor contactor coil

MV (2 terminals)

 

gas valve (both gas solenoids are connected in parallel)

TR

 

24 VAC transformer (low voltage COMMON side)

TH

 

24 VAC transformer (low voltage HIGH side)

RO1

 

rollout switch OUTPUT

RO2

12-pin

rollout switch INPUT

FP

connector

flame sensor probe*

PS

& harness

pressure switch INPUT

HLI

 

high limit INPUT

HLO

 

high limit OUTPUT

GND

 

MUST BE RELIABLY GROUNDED TO CHASSIS

(unused terminal)

 

 

IND

4-pin

inducer HOT side

IGN

ignitor HOT side

connector

IND N

inducer NEUTRAL side

& harness

IGN N

ignitor NEUTRAL side

 

COOL

14” spade terminal

circulator blower COOL SPEED terminal

HEAT

14” spade terminal

circulator blower HEAT SPEED terminal

PARK (2 terminals)

14” spade terminal

unused circulator blower terminals

LINE

14” spade terminal

input voltage (120 VAC) HOT side

XFMR

14” spade terminal

24 VAC transformer line voltage HOT side

EAC (optional)

14” spade terminal

electronic air cleaner HOT side

HUM (optional)

14” spade terminal

humidifier HOT side

CIR N

14” spade terminal

circulator blower NEUTRAL terminal

LINE N

14” spade terminal

input voltage (120 VAC) NEUTRAL side

XFMR N

14” spade terminal

24 VAC transformer line voltage NEUTRAL side

EAC N (optional)

14” spade terminal

electronic air cleaner NEUTRAL side

HUM N (optional)

14” spade terminal

humidifier NEUTRAL side

* maximum recommended flame probe wire length is 36 inches.

5

Page 5
Image 5
White Rodgers 50a55-286 Typical System Wiring Table, 50A55, Terminal, System Component, Type, Connection