Equipment

Troubleshooting Assistance Guide

 

Equipment

Fan will not turn Off.

 

• The thermostat fan setting may be in the On position. In this position, the fan will

 

 

 

 

continuously run. Change it to the Auto position.

 

 

• Thermostat may be currently calling for heat or cool. This is normal operation. Fan

 

 

will turn off automatically once the heating/cooling is satisfied if fan is in Auto mode.

 

 

• With fan in Auto mode and heating and cooling system is not operating, the fan will

 

 

not shut off. The air handler fan relay switch is likely bad. Call your heating and

 

 

cooling contractor.

 

 

• Heating/Cooling equipment has an internal fan overrun where the fan continues to run

 

 

after the heating or cooling unit turns off. Typical fan overrun times are 1-2 minutes

 

 

following the heat or cool system shut down.

 

 

Fan will not turn On.

 

 

Some heating and cooling equipment, especially gas furnaces, have a built-in time delay

 

 

before the fan is activated (plenum switch or fan timer). It may take up to 90 seconds. A

 

 

temperature sensor in the top of the air handler activates the fan on a gas furnace.

 

 

Set the heating setpoint 5 degrees above the room temperature. Wait 5 minutes for the fan

 

 

to be activated. If the fan does not activate, call your heating and cooling contractor.

 

 

 