TROUBLESHOOTING

Problem

Possible Causes

 

Solutions

 

 

 

 

The portable air

 Power failure / outage

 

 Restore the power supply

conditioner does not

 The automatic switch, line

 

 Flip the switch / change the fuse / turn the

turn on

fuse, or breaker has been

 

breaker back on. Also note that you may have

 

tripped

 

too many appliances drawing power on one

 

 

 

circuit, you may need to move the other

 

 The power supply voltage is

 

appliances to another circuit

 

 

 Move the unit onto another circuit with the

 

too low

 

correct voltage

 

 The power cord is damaged

 

 Call for service. Only authorized personnel

 

 

 

should replace damaged power cord or power

 

 The L.C.D.I. power plug for

 

plug

 

 

 Press the Reset button on the L.C.D.I. power

 

the unit is tripped

 

plug

 

 The internal water reservoir

 

 Drain water from the air conditioner

 

is full and ‘P1” appears on

 

 Possible loose internal connection. Please

 

display

 

contact Whynter for service

 

 

 

 

The unit turns on but

 The room temperature is

 

 This unit is designed to work in ambient

the compressor does

outside of the operational

 

temperatures of 64°F to 90°F

not turn on (the fan runs

tolerances of the unit

 

 

but the unit is not

 The Cooling mode is not on

 

 Press the MODE button until the COOL light is

cooling)

 The compressor has not

 

shown on the display

 

 

 Give the compressor 3 minutes to turn on after

 

turned on yet because of its

 

the Cooling mode has been selected

 

time delay

 

 

 

 The set temperature is too

 

 Set the air conditioner to a lower temperature.

 

high

 

It is recommended to set the temperature to at

 

 

 

least 5°F of the ambient temperature

 

 The internal water reservoir

 

 Either manually drain the water by removing

 

 

the drain plug or allow the unit to exhaust the

 

is full and ‘P1” appears on

 

water itself by running the fan only mode.

 

display

 

Then cooling will resume

 

 

 

 Possible loose internal connection. Please

 

 

 

contact Whynter for service

 

 

 

 

The air coming out of

 The filters are dirty or

 

 Clean the air filters

the unit is not very cold,

obstructed

 

 

or the airflow volume is

 The air intake or exhaust is

 

 Make sure there is at least 20" of clearance

weak

obstructed

 

from the air intake. Make the length of the

 

 The unit is set in DRY or

 

exhaust hose is as short as possible

 

 

 Set the unit to the cooling mode

 

FAN mode

 

 

 

 The unit is set to low fan

 

 Set the unit to a higher fan speed

 

speed

 

 

 

 

 

 

 

19 P a g e

 