TROUBLESHOOTING
Problem | Possible Causes |
| Solutions |
|
|
|
|
The portable air | Power failure / outage |
| Restore the power supply |
conditioner does not | The automatic switch, line |
| Flip the switch / change the fuse / turn the |
turn on | fuse, or breaker has been |
| breaker back on. Also note that you may have |
| tripped |
| too many appliances drawing power on one |
|
|
| circuit, you may need to move the other |
| The power supply voltage is |
| appliances to another circuit |
|
| Move the unit onto another circuit with the | |
| too low |
| correct voltage |
| The power cord is damaged |
| Call for service. Only authorized personnel |
|
|
| should replace damaged power cord or power |
| The L.C.D.I. power plug for |
| plug |
|
| Press the Reset button on the L.C.D.I. power | |
| the unit is tripped |
| plug |
| The internal water reservoir |
| Drain water from the air conditioner |
| is full and ‘P1” appears on |
| Possible loose internal connection. Please |
| display |
| contact Whynter for service |
|
|
|
|
The unit turns on but | The room temperature is |
| This unit is designed to work in ambient |
the compressor does | outside of the operational |
| temperatures of 64°F to 90°F |
not turn on (the fan runs | tolerances of the unit |
|
|
but the unit is not | The Cooling mode is not on |
| Press the MODE button until the COOL light is |
cooling) | The compressor has not |
| shown on the display |
|
| Give the compressor 3 minutes to turn on after | |
| turned on yet because of its |
| the Cooling mode has been selected |
| time delay |
|
|
| The set temperature is too |
| Set the air conditioner to a lower temperature. |
| high |
| It is recommended to set the temperature to at |
|
|
| least 5°F of the ambient temperature |
| The internal water reservoir |
| Either manually drain the water by removing |
|
| the drain plug or allow the unit to exhaust the | |
| is full and ‘P1” appears on |
| water itself by running the fan only mode. |
| display |
| Then cooling will resume |
|
|
| Possible loose internal connection. Please |
|
|
| contact Whynter for service |
|
|
|
|
The air coming out of | The filters are dirty or |
| Clean the air filters |
the unit is not very cold, | obstructed |
|
|
or the airflow volume is | The air intake or exhaust is |
| Make sure there is at least 20" of clearance |
weak | obstructed |
| from the air intake. Make the length of the |
| The unit is set in DRY or |
| exhaust hose is as short as possible |
|
| Set the unit to the cooling mode | |
| FAN mode |
|
|
| The unit is set to low fan |
| Set the unit to a higher fan speed |
| speed |
|
|
|
|
|
|