Maintenance

1)Do not use any commercial chemical cleaning agent, acidic agent, naphtha decontamination powders, etc to clean the machine. Our recommended cleaning agent is vinegar and water solution.

2)Cleaning agent must be added through the manual fill compartment (10) only.

3)Do not allow water to be in the reservoir for more than a few days. The water reservoir should be drained and the SELF CLEAN function should be used.

4)To prevent injury, please do NOT touch the ICE or WATER outlets while the machine is switched ON.

5)If any part of this machine fails or is damaged, please contact our service department.

Troubleshooting

TROUBLE

 

REASON

WHAT TO DO

 

 

 

1. Plug into mains power

There is no POWER light

1.

No power

supply.

2.

Fuse blown

2. Replace fuse; unscrew

on

 

 

fuse holder (part 14) and

 

 

 

 

 

 

replace fuse

Power light on but the

 

 

Voltage must be 110v AC

compressor is not working

Incorrect voltage

60HZ earthed mains supply

(buzzing noise only)

 

 

 

 

 

Orange flashing light

Low water level or

Fill water manually/ Change

water bottle or turn on water

(no/low water) is on

no water in reservoir.

line

 

 

 

Water has poor taste or

Unit needs to be

See cleaning section

odour

sanitized.

 

Particles floating in water

Water has high mineral

Use water with less

content.

hardness.

 

 

 

 

Compressor is working but

1. Low water level

1. Fill water

not dispensing ice or

2. Mineral deposits

2. Clean the unit

water

clogging tanks.

 

 

 

 

1. Turn on the unit using

 

 

 

the On/Off switch and

 

1. Unit is not switched on.

press the Start button. Hold

 

 

 

a glass of water about 5

 

 

 

inches above fill

 

 

 

compartment and pour

 

 

 

water into unit.

Unit does not take in water

 

 

2. Make sure that the red

2. The water level

ball is floating

 

 

indicator (red ball) is not

3. The unit stops taking in

 

moving.

 

 

 

water when the water tank

 

3. Water tank is about

is about half full.

 

half full

4. Replace fuse; unscrew

 

 

 

 

3. Fuse blown

fuse holder (part 14) and

 

 

 

replace fuse

Unit does not take in water

1. Bottle supporter is not

1. Maker sure the bottle

installed properly

supporter is properly

from a water bottle

 

 

installed with the arrow

 

 

 

Page 6