TO BEGIN SCRUBBING

When operating the machine around people, pay close attention for unexpected movement. Use extra caution around children.

Flammable liquids and/or reactive metals can cause explosions or fire! Do not pick up.

1.Lower the squeegee.

2.Turn the vacuum on.

3.Lower the scrub brush to the floor.

4.Turn the scrub brush on.

5.Push machine forward to begin scrubbing.

NOTE: Shut machine off immediately if water or foam is expelled from the machine.

6.Adjust the solution flow as necessary.

TO STOP SCRUBBING

1.Turn the scrub brush off.

2.Raise the scrub brush.

3.Raise the squeegee.

4.Turn the vacuum off.

DOUBLE SCRUB

For floors, which are heavily soiled or have thick accumulations of floor finish the machine may not clean sufficiently with one pass. In these cases it will be necessary to double scrub. To double scrub, make the first pass over the surface being cleaned with the squeegee up, vacuum off, the solution on, and brush down and on. This allows the solution to stay in contact with the soil while loosening the surface accumulation with the brush. Allow time for the first application to stay in contact with the floor.

MACHINE OPERATION

The length of time between the first and second pass depends on the amount of accumulation and the type of chemical being used. A second scrubbing with the squeegee down, vacuum on and again with solution and brush on will further loosen the soil. The additional application of solution will further assist the difficult cleaning job.

FOR SAFETY: When using machine, go slow on inclines and slippery services.

EMPTYING AND CLEANING TANKS

1.Park the machine next to a drain. Drain hoses are on the rear of the machine.

2.Turn the machine off.

SOLUTION TANK

1.Pull the small drain hose from the retainer. Lower the hose in the direction of the drain.

2.Remove the solution tank cover.

3.Flush the solution tank out with clean water and run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to clean the tank, damage may occur.

NOTE: Never allow solution to remain in tank. Damage to tank, seals and valves could occur.

4.Replace drain hose to retainer.

RECOVERY TANK

1.Unhook the large drain hose from the retainer. Lower the hose in the direction of the drain. Do not stand in front of the end of the hose.

Recovered solution will come out with force. Slowly remove the plug from the drain hose.

2.Flush the recovery tank out with clean water. Do not use water hotter than 140°F (60°C) to clean the tank, damage may occur.

3.Clean off the float and check for free movement of the float ball.

4.Replace the drain plug and secure the drain hose in the retainer.

86221970 17” SCRUBBER 01/03/07

3-8

Page 15
Image 15
Windsor 10066220, HCC172, SCHC172, SCC172 manual Machine Operation, Emptying and Cleaning Tanks, Solution Tank, Recovery Tank

10066210, 10066270, 10052700, SCH172, 10066230 specifications

Windsor is a renowned name in the realm of technology and innovation, prominently recognized for its advanced cooling solutions and HVAC technologies. Within its impressive portfolio, models such as SCHC172, SCC172, QSCC172IA, 10066260, and 10066220 stand out due to their remarkable features and capabilities.

The SCHC172 model is designed specifically for high-efficiency cooling applications, ideal for both commercial and industrial use. One of its main features includes a robust compressor that significantly enhances the unit's performance and reliability. This model operates with variable speed technology, allowing for better energy management and cost-effectiveness while maintaining optimal cooling conditions.

SCC172, on the other hand, is engineered with a focus on sustainability. It utilizes eco-friendly refrigerants that comply with contemporary environmental standards, minimizing the carbon footprint associated with cooling systems. Moreover, it incorporates advanced diagnostic capabilities that facilitate real-time monitoring and maintenance, ensuring the unit operates at maximum efficiency.

The QSCC172IA model takes innovation a step further by integrating smart technology. This model features an IoT-enabled interface that allows for remote operation and monitoring. Users can control the cooling settings from their smartphones or computers, providing unprecedented convenience and control. The QSCC172IA also includes automated energy-saving features that adjust the system based on current load requirements.

Models 10066260 and 10066220 are tailored for specific industrial applications, featuring heavy-duty construction that withstands rigorous operational conditions. These models boast superb thermal performance and are composed of corrosion-resistant materials that extend their lifespan. With user-friendly interfaces and customizable settings, they can cater to a variety of cooling requirements.

Collectively, these models from Windsor exemplify the brand's commitment to innovation, efficiency, and sustainability in the HVAC sector. By incorporating advanced technologies, eco-friendly materials, and user-focused designs, Windsor not only meets the demanding cooling needs of today's industries but also leads the charge towards a more sustainable future. Their models embody the balance of performance and responsibility that modern consumers seek in technologically advanced cooling solutions. Whether for industrial, commercial, or smart environments, Windsor's products deliver high efficiency and reliability, ensuring comfort and performance year-round.