Windsor 10066270, HCC172 Maintenance, CHECKING GRAVITY A.Hydrometer B.Battery, Battery Condition

Models: 10066210 10066270 10052700 SCH172 10066230 SCHC172 QSCC172 10066080 10066220 10066240 QSCC172IA HCC172 10066300 10066350 SCC172 10066260 10066310 10066250 10066320 10066330

1 24
Download 24 pages 58.04 Kb
Page 17
Image 17
CHECKING GRAVITY

CHECKING BATTERY SPECIFIC GRAVITY Use a hydrometer to check the battery specific gravity.

Battery Check

CHECKING GRAVITY

A.Hydrometer

B.Battery

NOTE: Do not take readings immediately after adding distilled water, if the water and acid are not thoroughly mixed, the reading may not be accurate.

Check the hydrometer readings against this chart.

SPECIFIC GRAVITY

BATTERY CONDITION

@ 80° F (27°C)

 

1.265

100% CHARGED

1.225

75% CHARGED

1.190

50% CHARGED

1.155

25% CHARGED

1.120

DISCHARGED

NOTE: If the readings are taken when the battery electrolyte is any temperature other than 80°F (27°C), the reading must be temperature corrected.

To find the corrected specific gravity reading when the temperature of the battery electrolyte is other than 80°F (27°): Add (+) to the specific gravity reading 0.004 (4 points), for each 10°F (6°C) above 80° (27°C).

Subtract (-) from the specific reading 0.004 (4 points), for each 10°F (6°C) below 80°F (27°C)

MAINTENANCE

TO CHARGE THE BATTERIES

When servicing machine, avoid contact with battery acid.

Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging.

Wear eye protection and protective clothing when working with batteries.

Charge batteries in a well ventilated area. Leave the solution tank open.

MACHINES EQUIPPED WITH ONBOARD CHARGER

1.Fully open Recovery Tank/Battery Cover or prop in partially open position using bracket (included). This will provide additional venting of batteries during charging cycle.

2.Connect charger’s AC power cord to AC mains. The charger’s YELLOW “AC” LED will light.

NOTE: When charger is energized, all machine function will shut down.

3.After several seconds, the charger’s green LED will flash to indicate that charging is in process.

NOTE: If no lights are illuminated, or yellow LED flashes, refer to the charger Product Manual Troubleshooting section.

4.When charging is complete, both the yellow and green LEDs will remain on. The charger is now in standby mode.

5.Disconnect charger’s AC power cord.

6.Raise battery cover and check the battery electrolyte level. It should be up to the indicator ring. If necessary, add distilled water.

7.Lower the battery cover

NOTE: For additional information about battery charger function, please see the charger Product Manual.

86221970 17” SCRUBBER 01/03/07

4-2

Page 17
Image 17
Windsor 10066270, HCC172 Maintenance, CHECKING GRAVITY A.Hydrometer B.Battery, Battery Condition, To Charge The Batteries