TROUBLESHOOTING

 

 

TROUBLESHOOTING

 

 

 

 

PROBLEM

CAUSE

SOLUTION

 

Little or no solution flow to the floor

Solution tank empty

Fill solution tank

 

 

 

 

 

 

Solution flow turned off or set

Turn on or increase flow

 

too low

setting

 

 

Solution strainer plugged

Clean solution strainer

 

 

 

 

 

 

Solution hoses obstructed

Clear obstruction from hose

 

 

 

 

 

Solution solenoid valve

Clean or replace

 

obstructed or stuck

 

 

No power to machine

Battery disconnected

Check all battery cable

 

 

 

connections

 

 

Emergency shut-off activated

Reset

 

 

 

 

 

 

Battery connections corroded

Clean connections

 

Faulty main contactor

Replace contactor

 

 

 

 

 

 

Faulty power switch

Replace switch

 

 

 

 

 

 

 

 

 

 

Machine turned on with

Allow control button to return

 

 

directional control button(s)

to neutral. Restart

 

 

not in neutral

 

 

 

 

 

 

 

Loose connection

Check motor wires and

 

 

 

connection

 

86221970 17” SCRUBBER 01/03/07