Windsor 10052340 4-12, Actuator Scrub Deck Removal/Replacement, Scrub Deck Actuator Adjustment

Models: 10052340 SCEOX326 10052310 SCEX326

1 32
Download 32 pages 18.44 Kb
Page 30
Image 30

12.ACTUATOR SCRUB DECK REMOVAL/REPLACEMENT

FOR SAFETY: Before leaving or servicing machine, stop on a level surface, turn off machine and set parking brake (If option is installed).

1.Remove front cover.

3.Remove the two nuts below the scrub deck that attach the actuator bracket.

4.Remove clevis pin and rue ring from lower bracket of actuator, make sure not allow actuator bracket to rotate.

5.Disconnect actuator from wiring harness.

6.Remove upper clevis pin and rue ring from actuator bracket.

7.Reverse steps to install.

MAINTENANCE

SCRUB DECK ACTUATOR ADJUSTMENT

The actuator will need to be adjusted when replaced.

To adjust the actuator:

1.While holding actuator barrel to prevent it from spinning, apply power to the actuator such that it is fully extended. Positive power to white wire, and negative/ground to black. Limit switch within actuator will stop it.

2.Turn barrel out one or more full turns to assure that when it is retracted it will not bind against itself.

3.While holding actuator barrel to prevent it from spinning, apply power to the actuator such that it is fully retracted. Positive power to black wire, and negative/ground to white wire. Limit switch within actuator will stop it.

4.With actuator fully retracted, turn barrel in until it touches the base of the threaded shaft.

5.At the bottomed out position, turn the barrel out 1 1/2 turns, then enough more to allow connection to lift linkage.

6.Connect actuator to lift linkage.

7.Check travel of actuator during operation.

4-12

CUTTER 36V (SCEX) 86037040 12/12/06

 

Page 30
Image 30
Windsor 10052340, SCEX326 4-12, Actuator Scrub Deck Removal/Replacement, Scrub Deck Actuator Adjustment, Maintenance