MACHINE OPERATION

DOUBLE SCRUB

For floors which are heavily soiled or have thick accumulations of floor finish may not clean sufficiently with one pass. In these cases it will be necessary to double scrub.

To double scrub, make the first pass over the surface being cleaned with the squeegee up, vacuum off, the solution on, Aqua-Mizer removed and brushes down. This allows the solution to stay in contact with the soil while loosening the surface accumulation with the brushes. Allow time for the first application to stay in contact with the floor. Length of time between the first and second pass depends on amount of accumulation and the type of chemical being used. A second scrubbing with the squeegee down and again the solution and brushes on will further loosen soil. The additional application of solution will further assist the difficult cleaning job.

FOR SAFETY: When using machine, go slow on inclines and slippery services.

EMPTYING AND CLEANING TANKS

1.Park the machine next to a floor drain. Drain hose is on left rear corner of the machine.

2.Turn the machine power off and set parking brake, if your machine is equipped with this option.

SOLUTION TANK

1.Loosen small drain hose from the retainer, then lower hose in direction of the drain.

2.Remove the solution tank cover.

3.Flush the solution tank out with clean water and run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur.

NOTE: Never allow solution to remain in tank. Damage to tank, seals and valves could occur.

4.Secure drain hose into the retainer.

RECOVERY TANK

1.Unhook the large drain hose from the retainer. Unscrew the T-handle on plug enough to loosen plug, then lower hose in direction of the drain. Do not stand in front of end of hose. Recovered solution will come out with force. Slowly remove plug from drain hose.

2.Remove the recovery tank dome. Flush the recovery tank out with clean water. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur.

3.Clean off the float shut-off system and inspect for free movement of float. The float shut-off system is located in the rear of the recovery tank.

4.Replace the drain plug and secure drain hose in bracket.

5.If machine is to be stored, leave the recovery tank dome off.

RECOVERY

RECOVERY

TANK COVER

TANK DRAIN

SOLUTION

TANK COVER

SOLUTION

TANK DRAIN

3-11

CUTTER 36V (SCEX) 86037040 12/12/06

Page 18
Image 18
Windsor 10052340, SCEX326, SCEOX326, 10052310 manuel dutilisation Double Scrub, Emptying and Cleaning Tanks