Winegard RM-9946, RM-9947 operation manual Front of Vehicle, Center Line Coach Roof

Models: RM-9947 RM-9946

1 20
Download 20 pages 36.65 Kb
Page 12
Image 12

FIGURE 6

FRONT OF VEHICLE

Cable-entry plate

CENTER LINE

OF COACH

ROOF

4” MINIMUM from

First cable

first clamp to

clamp here!

cable-entry plate

 

4”

 

20”

16”

16” from front center edge of mount base

The length of this cable MUST BE 53 inches from back of electronics housing to clamp. NO CLAMPS ALONG THIS 53” LENGTH!

PASSENGER

SIDE

DRIVER

SIDE

FIGURE 6A

 

Cable-entry plate

 

Cable clamps ev-

First cable

 

clamp here!

Cable-en-

ery 12” from first

 

try plate

cable clamp

 

The length of this cable MUST BE 53 inches from back of electronics housing to clamp. NO CLAMPS ALONG THIS 53” LENGTH!

PASSENGER

FRONT OF VEHICLE

CENTER LINE OF

COACH ROOF

Cable-en- try plate

20”

16”

16” from front center edge of mount base

SIDE

DRIVER SIDE

FIGURE 6B

Cable clamps every 12” from first cable clamp

FRONT OF VEHICLE

First cable clamp here!

CENTER LINE OF

COACH ROOF

20”

16”

16” from front center edge of mount base

The length of this cable MUST BE 53 inches from back of electronics housing to clamp. NO CLAMPS ALONG THIS 53” LENGTH!

PASSENGER

SIDE

DRIVER

SIDE