W1761/W1762 12" Table Saw with Riving Knife

The machine must be properly set up before it is safe to operate. DO NOT connect this machine to the power source until instructed to do so in the "Test Run" portion of this manual.

W1762 220V 3-Phase

Operation

The Model W1762 is prewired for 220V 3-phase opera- tion, but may be rewired for 440V 3-phase operation. We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit size given below. Never replace a circuit breaker with one of higher amperage without consulting a qualified electrician to ensure compliance with wiring codes. This machine must be connected to a grounded circuit!

L15-30 P

L15-30 R

Locking

Shutoff Switch

ELECTRICAL

If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire or circuit overload hazard— consult a qualified electrician to reduce this risk.

W1762 440V 3-Phase

Operation

If rewired to 440V operation, the Model W1762 must be hardwired to a locking shutoff switch by a qualified elec- trician. Hardwiring involves a permanent installation with conduit runs that can only be accomplished safely by a qualified electrician. As always, observe all applicable electrical codes when connecting this machine to power.

Phase Converter

The power from the manufactured power leg (wild wire) of a phase converter fluctuates, which may damage elec- trical components if connected to the wrong power termi- nal. If you must use a phase converter for 3-phase power, ONLY connect the "wild wire" to the L3 terminal.

The wire going to the L3 terminal can handle some fluc- tuation because it goes directly to the motor. The power going to the L1 and L2 terminals goes to the transformer and must be consistent to prevent damage.

Electrical Specifications

Figure 8. NEMA L15-30 plugs and recep-

tacles and locking shutoff switch.

DO NOT work on your electrical system if you are unsure about electrical codes and wiring! Seek assistance from a qualified electrician. Ignoring this warning can cause electrocution, fire, or machine damage.

Rewiring to 440V

Rewiring your Model W1762 to 440V requires you to rewire the motor, switch the transformer fuse from 220V to 440V, and change the amperage dial of the ther- mal overload relay from 22 to 11 Amps. Refer to the photos on Page 57 and the wiring diagram on Page 59 for details.

Voltage

Amp Draw

Min. Circuit Size

Connection

Cord

Extension Cord

220V

19

30A

L15-30 Plug (Fig. 8)

10 Gauge, 4 Wire, 300V

10 Gauge

440V

10

15A

Hardwire

Conduit Setup

N/A (Hardwire Only)

-13-

Page 27
Image 27
Woodstock W1761/W1762 owner manual W1762 220V 3-Phase Operation, W1762 440V 3-Phase Operation, Phase Converter, Rewiring to