Woodstock W1814 manual KiflYc\jffk`e, Dfkfic\Zki`ZXc

Models: W1814

1 44
Download 44 pages 38.66 Kb
Page 35
Image 35

N(/(+Fne\ijDXelXcD]^%('&'/"

KiflYc\j_ffk`e^

This section covers the most common problems and corrections with this type of machine. N8IE@E>;FEFKdXb\XepX[aljkd\ekjlek`cgfn\i`j[`jZfee\Zk\[Xe[ dfm`e^gXikj_Xm\Zfd\kfXZfdgc\k\jkfg

Dfkfi<c\Zki`ZXc

GIF9C<D

GFJJ@9C<:8LJ<

 

:FII<:K@M<8:K@FE

Machine does not start or 1.

Safety key removed from ON/OFF

1.

Replace safety key.

a breaker trips.

switch.

 

 

2.

Plug/receptacle is at fault or wired

2.

Test for good contacts; correct the wiring.

 

incorrectly.

 

 

3.

Power supply is at fault/switched

3.

Ensure hot lines have correct voltage on all legs and

 

OFF.

 

main power supply is switched ON.

4.

Lockout key is at fault.

4.

Install/replace lockout key; replace switch.

5.

Motor brushes are at fault.

5.

Remove/replace brushes.

6.

Motor ON/OFF switch is at fault.

6.

Replace faulty ON/OFF switch.

7.Wiring is open/has high resistance. 7. Check for broken wires or disconnected/corroded connections, and repair/replace as necessary.

 

8.

Motor is at fault.

8.

Test/repair/replace.

Machine stalls, is

1.

Wrong workpiece material (wood).

1.

Use wood with correct moisture content, without

underpowered, or is

 

 

 

glues, and little pitch/resins.

overloaded.

2.

Cutterhead belt slipping.

2.

Replace cutterhead belt and re-tension.

 

 

3.

Plug/receptacle is at fault.

3.

Test for good contacts; correct the wiring.

 

4.

Motor brushes are at fault.

4.

Remove/replace brushes.

 

5.

Motor bearings are at fault.

5.

Test by rotating shaft; rotational grinding/loose

 

 

 

 

shaft requires bearing replacement.

 

6.

Machine is undersized for the task.

6.

Stop operation.

 

7.

Knives dull, feed rate is too fast

7.

Use sharp knives; reduce feed rate/depth of cut.

 

 

depth of cut too great.

 

 

 

8.

Motor has overheated.

8.

Clean off motor, let cool, and reduce workload.

 

9.

Motor is at fault.

9.

Test/repair/replace.

 

 

 

 

 

Machine has vibration or

1.

Motor or component is loose.

1.

Inspect/replace stripped or damaged bolts/nuts,

noisy operation.

 

 

 

and re-tighten with thread locking fluid.

 

2.

Knife blades, clamp or jack screws

2.

Resharpen/replace knives as required; set knife

 

 

are at fault.

 

alignment correctly.

 

3.

Belts worn or loose.

3.

Inspect/replace belts with a new ones.

4.Motor fan is rubbing on fan cover. 4. Replace dented fan cover; replace loose/damaged fan.

5.

Loose mounting bolts.

5.

Replace/tighten as required.

6.

Blade is at fault.

6.

Replace warped, bent, or twisted blade; resharpen

 

 

 

dull blade.

-33-