ISM4 INSTALLATION & PROGRAMMING MANUAL | 25 |
system upon detection of a change of state on any Source Sense Input. This feature can be enabled/disabled via the Enable/Disable Automatic Source Power Notification Commands explained in the ISM4 RS232 Command Strings Table above.
The Source Power Notification Data String contains Power Status information for all four Sources. The Notification Data Structure is preceded by the ‘#’ character prefix and terminated with the ‘+’ character. The Notification Data String is parsed into four fields. Each field holds one Source Component State Data Structure (one per Source Component). Each Source Component Data Structure holds information that identifies the particular source component and its power state, as indicated by the definition of {0/1}, a ‘0’ indicates the OFF condition. A ‘1’ indicates an ON condition.
Example
#SS{S#} PR{0/1}
SS{S#} PR{0/1}
SS{S#} PR{0/1}
SS{S#} PR{0/1}+
The SS{S#} field indicates which Source is being reported. All data that follows will pertain to that Source. The end of the current field will be flagged by the presence of another SS{S#} field (next Source) or the ‘+’ termination character (end of report).
The PR{0/1} field indicates the Power State of the reported Source. That is, it indicates the Power State of the Source identified by the SS{S#} field that immediately precedes it.
The string below is an example of a string that might be sent out by the ISM4:
#SS1 PR1 SS2 PR1 SS3 PR0 SS4 PR0+ This string indicates the following: Source 1 Power State = ON
Source 2 Power State = ON
Source 3 Power State = OFF
Source 4 Power State = OFF
The System Info Query can be useful in determining the build of a particular ISM4. On occasion, Xantech Technical Personnel may ask for this information should a problematic situation occur.
ISM4 QUERIES
Name | Query | Return | Example Return | Remarks |
Source Power | ?{s#}PR+ | ?{s#}PR{0/1}+ | ?1PR0+{CR} | Power in Zone 1 is |
|
|
|
| OFF |
System Info | ?SI+ | ?SI | ?SI | NOTE: This is |
|
| {Device: | Device: | command does not |
|
| IPM4, | IPM4, Device | trickle down to the |
|
| Device Cde: | Cde: | Expansion Port. |
|
| 000F, | 000F, |
|
|
| Hardware Cde: | Hardware Cde: | X = Major |
|
| 0000, | 0000, | Y = Minor |
|
| Reserved Cde: | Reserved Cde: | Z = Release |
|
| 0000, | 0000, |
|
|
| Firmware Ver: | Firmware Ver: |
|
|
| X.Y.Z}+ | 1.0.0 |
|
NOTE: Allowable Syntax for the Queries includes: (Source 1 Power used for example) ?1PR+
?01PR+
RS232 Command String/Query Legend
{CR} = Carriage Return
{s#} = Source Input Number Range