Jazz 300.book Page 37 Thursday, February 28, 2002 11:36 AM

 

 

 

 

Troubleshooting Reference

 

 

 

 

Table 4

Troubleshooting reference
Problem

 

Possible Cause

 

Solution

 

 

 

 

 

 

AC appliance

AC appliance rated

 

Use an AC appliance with a power

will not

 

more than 300 watts,

 

rating less than 300 watts.

operate;

 

safety overload has

 

 

audible alarm

tripped.

 

 

is not

 

 

 

AC appliance may exceed Jazz PP

sounding.

 

AC appliance is rated

 

 

 

less than 300 watts,

 

300 C’s surge capability. Use an AC

 

 

high starting surge has

 

appliance with a starting surge

 

 

tripped safety

 

within the Jazz PP 300 C surge

 

 

overload.

 

rating.

 

 

 

 

AC appliance

Battery has discharged

 

Turn the AC Outlet On/Off switch

will not

 

to 10.0 volts.

 

off and recharge the Jazz PP 300 C.

operate;

 

Inverter has

 

Turn the AC Outlet On/Off switch

audible alarm

 

is sounding.

 

overheated due to poor

 

off and allow the Jazz PP 300 C to

 

 

ventilation or

 

cool for 15 minutes or more. Clear

 

 

excessively warm

 

blocked fan opening or remove

 

 

environmental

 

objects covering the unit, then restart

 

 

conditions.

 

the Jazz PP 300 C.

 

 

 

 

 

Run time is

 

Internal battery is not

 

Recharge using the AC Charger,

less than

 

fully charged.

 

until Recharge indicator is green.

expected.

 

AC appliance power

 

Check AC appliance power or

 

 

 

 

 

consumption is higher

 

wattage rating (or current draw for

 

 

than expected.

 

12 volt DC appliances) and compare

 

 

 

 

with tables “AC Appliances and Run

 

 

 

 

Times” on page 15 and “ 12 Volt

 

 

 

 

DC Appliances and Run Times” on

 

 

 

 

page 18.

 

 

 

 

 

37