Jazz 300.book Page 37 Thursday, February 28, 2002 11:36 AM
|
|
|
| Troubleshooting Reference |
|
|
|
| |
Table 4 | Troubleshooting reference | |||
Problem |
| Possible Cause |
| Solution |
|
| |||
|
|
|
| |
AC appliance | AC appliance rated |
| Use an AC appliance with a power | |
will not |
| more than 300 watts, |
| rating less than 300 watts. |
operate; |
| safety overload has |
|
|
audible alarm | tripped. |
|
| |
is not |
|
|
| AC appliance may exceed Jazz PP |
sounding. |
| AC appliance is rated |
| |
|
| less than 300 watts, |
| 300 C’s surge capability. Use an AC |
|
| high starting surge has |
| appliance with a starting surge |
|
| tripped safety |
| within the Jazz PP 300 C surge |
|
| overload. |
| rating. |
|
|
|
| |
AC appliance | Battery has discharged |
| Turn the AC Outlet On/Off switch | |
will not |
| to 10.0 volts. |
| off and recharge the Jazz PP 300 C. |
operate; |
| Inverter has |
| Turn the AC Outlet On/Off switch |
audible alarm |
| |||
is sounding. |
| overheated due to poor |
| off and allow the Jazz PP 300 C to |
|
| ventilation or |
| cool for 15 minutes or more. Clear |
|
| excessively warm |
| blocked fan opening or remove |
|
| environmental |
| objects covering the unit, then restart |
|
| conditions. |
| the Jazz PP 300 C. |
|
|
|
|
|
Run time is |
| Internal battery is not |
| Recharge using the AC Charger, |
less than |
| fully charged. |
| until Recharge indicator is green. |
expected. |
| AC appliance power |
| Check AC appliance power or |
|
|
| ||
|
| consumption is higher |
| wattage rating (or current draw for |
|
| than expected. |
| 12 volt DC appliances) and compare |
|
|
|
| with tables “AC Appliances and Run |
|
|
|
| Times” on page 15 and “ 12 Volt |
|
|
|
| DC Appliances and Run Times” on |
|
|
|
| page 18. |
|
|
|
|
|
37