Jazz 300.book Page 39 Thursday, February 28, 2002 11:36 AM
|
|
|
| Troubleshooting Reference |
|
|
|
| |
Table 4 | Troubleshooting reference | |||
Problem |
| Possible Cause |
| Solution |
|
| |||
|
|
|
|
|
Over- |
| Heat |
| Turn off the AC Outlet On/Off |
temperature |
|
|
| switch, and let the Jazz PP 300 C |
shutdown |
|
|
| cool down. |
|
|
|
| |
Alarm sounds | Internal battery is |
| Recharge the Jazz PP 300 C. | |
|
| nearly discharged. |
|
|
|
| (10.7 volts). |
|
|
|
| If you ignore this |
|
|
|
| warning, the Jazz PP |
|
|
|
| 300 C automatically |
|
|
|
| switches off when the |
|
|
|
| battery reaches 10.0 |
|
|
|
| volts. |
|
|
|
|
|
| |
Recharge light | Battery status reading |
| Allow Recharge cycle to go into | |
is amber |
| is incorrect during |
| Ready mode. |
(indicating |
| recharge. |
| Unplug the charging sources and any |
recharging) |
|
|
| |
while battery | Battery Level |
| appliances and let the Jazz PP 300 C | |
level indicates | indicators are only |
| rest for 15 minutes to get an accurate | |
full. |
| accurate when the Jazz |
| reading. |
|
| PP 300 C has been |
|
|
|
| disconnected from all |
|
|
|
| appliances and all |
|
|
|
| charging sources for |
|
|
|
| fifteen minutes. |
|
|
|
|
|
|
|
Compressor |
| The valve connector |
| Check that the valve connector is |
runs but won’t | may not be securely |
| securely on the valve stem before | |
inflate. |
| on the valve stem. |
| closing the thumb latch. |
|
| The item being |
| Check that the item being inflated |
|
| inflated may have a |
| has no leaks. |
|
| leak. |
| Check the compressor hose for any |
|
|
|
| |
|
|
|
| breaks or leaks at connections. |
|
|
|
|
|
39