Jazz 300.book Page 39 Thursday, February 28, 2002 11:36 AM

 

 

 

 

Troubleshooting Reference

 

 

 

 

Table 4

Troubleshooting reference

Problem

 

Possible Cause

 

Solution

 

 

 

 

 

 

 

Over-

 

Heat

 

Turn off the AC Outlet On/Off

temperature

 

 

 

switch, and let the Jazz PP 300 C

shutdown

 

 

 

cool down.

 

 

 

 

Alarm sounds

Internal battery is

 

Recharge the Jazz PP 300 C.

 

 

nearly discharged.

 

 

 

 

(10.7 volts).

 

 

 

 

If you ignore this

 

 

 

 

warning, the Jazz PP

 

 

 

 

300 C automatically

 

 

 

 

switches off when the

 

 

 

 

battery reaches 10.0

 

 

 

 

volts.

 

 

 

 

 

 

Recharge light

Battery status reading

 

Allow Recharge cycle to go into

is amber

 

is incorrect during

 

Ready mode.

(indicating

 

recharge.

 

Unplug the charging sources and any

recharging)

 

 

 

while battery

Battery Level

 

appliances and let the Jazz PP 300 C

level indicates

indicators are only

 

rest for 15 minutes to get an accurate

full.

 

accurate when the Jazz

 

reading.

 

 

PP 300 C has been

 

 

 

 

disconnected from all

 

 

 

 

appliances and all

 

 

 

 

charging sources for

 

 

 

 

fifteen minutes.

 

 

 

 

 

 

 

Compressor

 

The valve connector

 

Check that the valve connector is

runs but won’t

may not be securely

 

securely on the valve stem before

inflate.

 

on the valve stem.

 

closing the thumb latch.

 

 

The item being

 

Check that the item being inflated

 

 

inflated may have a

 

has no leaks.

 

 

leak.

 

Check the compressor hose for any

 

 

 

 

 

 

 

 

breaks or leaks at connections.

 

 

 

 

 

39