Jazz 300.book Page 38 Thursday, February 28, 2002 11:36 AM
Troubleshooting Reference
Table 4 | Troubleshooting reference | |||
Problem |
| Possible Cause |
| Solution |
|
| |||
|
|
|
|
|
Measured |
| Use of |
| Modified sinewave (MSW) output |
output voltage |
| of the Jazz PP 300 C requires true | ||
is too low. |
| voltmeter to read |
| RMS reading meter, such as Fluke |
|
| output voltage. |
| 87 series, for accurate measurement. |
|
| Battery is almost fully |
| Press Battery Status button and |
|
| discharged. |
| recharge the Jazz PP 300 C as |
|
|
|
| necessary. Battery Level indicators |
|
|
|
| are only accurate when the Jazz PP |
|
|
|
| 300 C has been disconnected from |
|
|
|
| all appliances and all charging |
|
|
|
| sources for fifteen minutes. |
|
|
|
|
|
The battery |
| No voltage is present |
| Connect battery clips of the jump- |
clips of the |
| at the battery clips of |
| start cable correctly to the external |
| the |
| battery. | |
cables measure | unless they are |
|
| |
zero volts. |
| properly connected to |
|
|
|
| the external battery. |
|
|
|
|
|
| |
Charging light | No AC power at wall |
| Ensure power is available at | |
is Off when |
| receptacle. |
| receptacle. |
AC Charger is | AC Charger is faulty. |
| Replace AC Charger. | |
connected |
|
| ||
|
|
|
|
|
Overload |
| Appliance power |
| Unplug the appliance and confirm |
shutdown |
| requirements exceed |
| that the appliance’s power |
|
| the capacity of the |
| requirement is 300 watts or less |
|
| Jazz PP 300 C. |
| before attempting to restart the |
|
|
|
| appliance. |
|
|
|
|
|
Extreme |
| Appliance power |
| Replace the fuse with a 40 A, 32 |
overload, 40 |
| requirements greatly |
| VDC automotive |
amp external | exceed the capability |
| which is available at many | |
fuse opens. |
| of the Jazz PP 300 C. |
| automotive parts stores. |
|
|
|
| Reduce appliance power |
|
|
|
| requirements to within power rating |
|
|
|
| of the Jazz PP 300 C. |
|
|
|
|
|
38