Xantrex Technology 400R manual Obtaining a Replacement Battery

Models: 400R

1 74
Download 74 pages 51.97 Kb
Page 51
Image 51
Obtaining a Replacement Battery

Replacing the Internal Battery

CAUTION

Discharging the internal battery below 10.0 V will damage the battery and shorten its life.

Obtaining a Replacement Battery

Replacement batteries are available from stores that specialize in and have a selection of lead acid, AGM (Absorbed Glass Mat) batteries.

Refer to Table 4-1 for a listing of batteries approved for use with the XPower Powerpack:

Table 4-1Approved Replacement Batteries

Replacement Battery

Where to Buy

 

 

Panasonic

Panasonic:

#LC–X1220P

Tel: 1-800-833-9626

(12 V 20 Ah)

web: www.pasc.panasonic.com

 

 

 

Digi-Key

 

Tel: 1-800-344-4539

 

 

EnerSys

EnerSys

#NPX–80

Tel: 1-800-962-1287 (Eastern US)

(12 V 20 Ah)

Tel: 1-800-423-4667 (Western US)

 

 

 

web: www.EnersysStationary.com

 

 

Replacing the Battery

WARNING: Shock or electrical hazard

Read this entire section before disassembling the unit.

Before attempting to replace the internal battery, make sure you:

Disconnect any charging cables, 12 V DC appliances, and AC appliances from the XPower Powerpack.