Troubleshooting Reference

 

 

 

 

 

Table 5-1Troubleshooting reference

 

 

 

Problem

 

Possible Cause

 

Solution

 

 

 

 

 

 

 

 

 

 

Green

 

The voltage at the AC

 

Use AC wall outlet that supplies

 

Charging

 

wall outlet is less than

 

120 V AC.

 

Status light is

 

120 V AC.

 

 

 

still flashing

 

 

 

 

 

and hasn’t

 

Internal battery is

 

Replace the battery.

 

changed to

 

permanently damaged.

 

 

 

steady after 50

 

 

 

 

 

hours of

 

 

 

 

 

charging.

 

 

 

 

 

 

 

 

 

 

 

The

 

The valve connector

 

Check that the valve connector is

 

compressor

 

may not be securely

 

securely placed on the valve stem

 

runs but won’t

 

placed on the valve

 

before closing the thumb latch.

 

inflate.

 

stem.

 

 

 

 

 

The item being

 

Check that the item being inflated

 

 

 

inflated may have a

 

has no leaks.

 

 

 

leak.

 

 

 

 

 

 

 

Check the compressor hose for any

 

 

 

 

 

breaks or leaks at connections.

 

 

 

 

 

 

 

The

 

The compressor may

 

Turn off the compressor and let it

 

compressor

 

have overheated from

 

cool down.

 

runs slowly.

 

excessive use.

 

 

 

 

 

Battery voltage is too

 

Check the condition of the internal

 

 

 

low.

 

battery. The battery may need to be

 

 

 

 

 

recharged or replaced.

 

 

 

 

 

 