Maintenance

Replacing the External Fuse

The replacement fuse must be rated at 250 A, 32 V DC. See page 2–9 for a diagram. To replace the external fuse:

1.Remove the fuse cover.

2.Unscrew the two bolts on the fuse.

3.Replace the fuse. Ensure that the replacement fuse is rated at 250 A, 32 V DC and is of the same type.

4.Tighten the fuse with the two bolts.

5.Replace the fuse cover.

4-10

975-0162-01-01

Page 54
Image 54