![](/images/new-backgrounds/1148941/148941101x1.webp)
Specifications
NOTE: These specifications refer to charger mode.
AC Input | Freedom HF 1000/1055 models | Freedom HF 1800 models |
|
|
|
Operating voltage range | ||
|
|
|
Nominal current | 5 AAC at 20 A charge, 120 VAC IN | 10 AAC at 40 A charge, 120 VAC IN |
|
|
|
Nominal frequency | 60 Hz | 60 Hz |
DC Input | Freedom HF 1000/1055 models | Freedom HF 1800 models |
|
|
|
Nominal voltage | 12.0 VDC | 12.0 VDC |
|
|
|
Min battery voltage for charging | 0.0 VDC | 0.0 VDC |
|
|
|
Max output voltage | 14.4 VDC | 14.4 VDC |
|
|
|
Nominal output current | User selectable: | User selectable: |
| 2A, 5A, 10A, 20A (Freedom HF 1000) | 2A, 10A, 20A, 40A |
| 5A, 15A, 35A, 55A (Freedom HF 1055) |
|
|
| |
Charger current derating | Charger current will automatically derate as internal temperature exceeds 80 °C, and input VAC | |
| approaches low transfer. | |
|
|
|
Efficiency at nominal output | ≥75% | ≥75% |
Other | Freedom HF 1000/1055 models | Freedom HF 1800 models |
|
| |
Battery type settings | Flooded (default), Gel, AGM, or | |
| Fixed (13.5V) |
|
|
| |
Charge algorithms | Three stages (Bulk, Absorption, and Float) | |
|
|
|
Independent battery banks | one (1) |
|
|
|
|
Regulatory Approvals | Freedom HF 1000/1055 models | Freedom HF 1800 models |
| ETL approved to CSA 107.1, UL458, and UL458 Marine Supplement (drip shield with product | |
| number | |
|
|
|
This guide for use by qualified installers only.
37 |