Installing the Inverter/Charger

Safe

Locate the inverter/charger away from battery in a

Orientation

To meet regulatory requirements, the Freedom SW

 

separate well ventilated compartment. Do not

 

230V must be mounted in one of the approved

 

install the inverter/charger in any compartment

 

mounting orientations. See Figure 5 on page 21.

 

containing flammable gases or liquids like gasoline.

 

 

Close to

The length and size of your DC cables will affect

 

 

battery

performance. Use the DC cables recommended in

 

 

compartment

Table 2 on page 13. The unit should not be installed

 

 

 

in the battery compartment due to the possible

 

 

 

presence of explosive hydrogen gas from the

 

 

 

batteries.

 

 

Protected from

Never place the inverter/charger directly above the

 

 

battery acid

batteries—gases from battery will corrode and

 

 

and gases

damage the inverter/charger. If the inverter/charger

 

 

 

is installed in a compartment above the batteries,

 

 

 

make sure there is a solid, gas-impermeable wall

 

 

 

dividing the two compartments.

 

 

 

However, flooded or wet cell batteries produce

 

 

 

flammable gases that can potentially be ignited and

 

 

 

therefore a safety hazard. If the batteries are sealed

 

 

 

(no caps to add water), then the Freedom SW 230V

 

 

 

can be mounted above the batteries if so desired (a

 

 

 

position outlined in the manual).

 

 

 

Never allow battery acid to drip on the inverter/

 

 

 

charger or its wiring when filling the batteries or

 

 

 

reading their specific gravity.

 

 

This guide for use by qualified personnel only.

975-0697-01-01

19

Page 33
Image 33
Xantrex Technology 815-2524-02, 815-3524 manual Safe