Using the Remote On/Off Switch
Using the Remote On/Off Switch
To operate the inverter from the remote On/Off switch:
1.Turn on the inverter’s On/Off switch.
Note: Leave this switch on during operation. Turning it off disables the remote switch.
2.Press the touch control button on the remote switch to turn the inverter on. The INVERTER ON indicator lights up.
Press the button again if you want to turn the inverter off. The INVERTER ON indicator goes off.
Testing the GFCI-Protected AC Outlet
The AC outlet on the Prowatt 1000 is a Ground Fault Circuit Interrupter (GFCI) outlet. This protects you against hazardous electrical shocks that could be caused by dampness, faulty mechanism, worn insulation, etc.
You might still feel shock, but the GFCI should cut it off quickly enough so an adult in normal health is not seriously injured (infants and small children may still be affected).
Test the GFCI periodically to make sure it is operating correctly.
To test the GFCI protection:
1.Turn the inverter on.
2.Plug a test lamp into the outlet.
3.Push the TEST button.
The RESET button should pop out and the power should turn off (the lamp should go out). If the lamp remains lit, or if the RESET button does not pop out, return the inverter to the place of purchase for service.
If the GFCI trips by itself at any time, reset it and perform the preceding test.