18 Freedom SW 3000 Installation Guide

Installing the Inverter/Charger
Step 1: Choosing a Location for the Inverter/Charger
The location of the inverter/charger is a key factor in system performance.
Allow sufficient clearance around the unit (recommended minimum
3inches (76 mm)) and install in a well-ventilated compartment to prevent
overheating and premature shutdown of the inverter/charger.
The inverter should only be installed in a location that meets the following
requirements:

FIRE AND EXPLOSION HAZARD

This equipment contains components that could produce arcs or sparks.
To reduce the risk of fire or explosion, do not install this equipment in
compartments containing batteries or flammable materials, or in locations
that require ignition-protected equipment. This includes any space
containing gasoline-powered machinery, fuel tanks, or joints, fittings, or
other connections between components of the fuel system.
Failure to follow these instructions will result in death or serious
injury.

HEAT HAZARD

Do not cover or obstruct the ventilation openings. Do not install this
equipment in a compartment with limited airflow. Overheating may
result.
Failure to follow these instructions will result in death or serious
injury.
Vent ilated Do not operate the inverter/charger in a closed-in
area or restrict ventilation in any way. The inverter/
charger requires air circulation to maintain
optimum operating temperature and provide best
performance. If the unit has inadequate ventilation,
it may shut down due to overheating.
The air vented through the openings should also
have a path to circulate away from the inverter/
charger.
Dry Do not allow water or other fluids to drip or splash
on the inverter/charger. Do not expose to rain, snow
or water.
Cool Normal air temperature should be between
32 °F and 140 °F (0 °C and 60 °C)—the cooler the
better within this range.
Clearance Allow as much space around the inverter/charger as
possible. Xantrex recommends that other objects
and surfaces be at least 3inches (76 mm) away
from the ventilation openings for best performance.