Troubleshooting

WARNING: Electrical shock and burn hazard.

Do not dismantle the PROwatt SW Inverter. It does not contain any user-serviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn.

Troubleshooting Reference

Condition

Possible Cause

Solution

 

 

 

E 0 1

Under Voltage (low

Recharge the battery.

 

input) shutdown

Check cables and

 

 

connection if secure.

 

 

 

E 0 1

Poor DC wiring

Use proper cable and

with persistent low

and/or poor battery

make secure

battery alarm.

condition

connections.

 

 

Charge the battery or

 

 

install a new battery.

 

 

 

E 0 2

Over Voltage (high

Make sure the

 

input) shutdown

inverter is connected

 

 

to a 12 V battery.

 

 

 

Condition

Possible Cause

Solution

 

 

 

E 0 3

Overload shutdown

Reduce the load

 

 

within the inverter’s

 

 

continuous power

 

 

rating.

 

 

 

E 0 4

Over temperature

Allow the inverter to

Heavy load is

shutdown

cool off and reduce

connected then AC

 

the load if

output becomes

 

continuous operation

unavailable.

 

is required.

 

 

 

E 0 4

Over temperature

Improve ventilation

Normal load is

shutdown

and make sure the

connected then AC

 

inverter’s ventilation

output becomes

 

openings are not

unavailable.

 

obstructed.

 

 

Reduce the ambient

 

 

temperature, if

 

 

possible.

 

 

 