Operation

To test (or reset) the GFCI protection:

1.Press the unit’s power switch to turn the inverter On.

2.Plug a test lamp into the AC outlet.

3.Push the TEST button.

Note: The RESET button should pop out and the power should turn Off (the lamp should go out). If the lamp remains lit, or if the RESET button does not pop out, the GFCI may not be functioning.

If the GFCI trips by itself at any time, reset it and perform the preceding test.

Reading the Front Panel Indicators

Indicator LEDs

If the Green LED is On, it indicates that the unit is On. Under normal operating conditions, the AC outlets and USB port have power. However, even under an error condition such as a shutdown, the Green LED may still remain On.

If the Red LED is on, it indicates an error or alarm condition and an error code is displayed on the digital display underneath the LED.

Digital Display

Under normal operating conditions, the digital display shows the input voltage (in volts) and the output power (in kilowatts).

Under error or alarm conditions, the digital display shows an error code and the Red LED turns on.

Description of LED and Digital Display Codes

LED

Digital Display

Description

 

 

 

Green

1 3.5

Example: 13.5 volts

 

 

 

Green

0.2 5

Example: 0.25 Kw (250 watts)

 

 

 

Red

E 0 1

Under voltage alarm and/or

 

 

Under voltage shutdown

 

 

 

Red

E 0 2

Over voltage shutdown

 

 

 

Red

E 0 3

Over load shutdown

 

 

 

Red

E 0 4

Over temperature shutdown

 

 

 

Red

E 1 0

Short circuit or output circuit

 

 

overheat

 

 

 

Note: The audio alarm will sound for five minutes. After five minutes, the unit will turn off.

Restarting After an AC Output Shutdown

1.Press and hold the unit’s power switch to turn it Off.

2.Remove all AC loads or let the unit cool down for 15 minutes.

3.Press and hold the unit’s power switch to turn it On.

16

Xantrex PROwatt™ SW Sine Wave Inverter Owner’s Guide

Page 26
Image 26
Xantrex Technology SW 2000 Reading the Front Panel Indicators, Restarting After an AC Output Shutdown, Indicator LEDs