Troubleshooting

Condition

Possible Cause

Solution

 

 

 

E 1 0

Short circuit

Check the AC

No output voltage.

 

wiring for a short

 

 

circuit.

 

Very heavy load

Remove the load.

 

Output circuit

Turn the unit off.

 

overheat

Let the unit cool

 

 

down, check the fan

 

 

for any obstructions

 

 

and clear it, or

 

 

reduce the load.

 

 

Turn the unit back

 

 

on.

 

 

 

Condition

Possible Cause

Solution

 

 

 

No output voltage;

The unit is off.

Turn the inverter on.

no voltage

No power to the

Check wiring to the

indication.

inverter.

inverter.

 

Inverter fuse open.

Have a qualified

 

Reverse DC polarity.

service technician

 

 

check and replace

 

 

the fuse if necessary.

 

 

Have a qualified

 

 

service technician

 

 

check and replace

 

 

the fuse, making

 

 

sure to observe

 

 

correct polarity.

 

 

 

The unit is on and

The GFCI device

Reset the GFCI. See

running but there is

tripped.

page 16 for

no AC output.

 

instructions.

 

 

 

20

Xantrex PROwatt™ SW Sine Wave Inverter Owner’s Guide

Page 30
Image 30
Xantrex Technology SW 1000, SW 600, SW 2000 manual Troubleshooting