XEROX WorkCentre 5735/5740/5745/5755/5765/5775/5790 Information Assurance Disclosure Paper
2.2.3. External Connections
Figure
Interface | Description / Usage |
|
|
FAX line 1, | Supports FAX Modem T.30 protocol only |
|
|
FAX line 2, | Supports FAX Modem T.30 protocol only |
|
|
USB Host Port | Software upgrade |
|
|
PSW USB Target Port | |
| and Xerox copier assistant |
|
|
Ethernet | 10/100/1000 Network connectivity |
|
|
Scanner | Proprietary connection between the scanner and controller |
| carrying power and communications |
|
|
Serial Port | Engineering development debug; default state is disabled |
|
|
Foreign Device Interface (FDI) | Allows connection of optional access control hardware |
|
|
Table 4 Controller External Connections
2.2.4. USB Ports
The WorkCentre contains a host connector for a USB flash drive, enabling upload of software upgrades and download of network logs or machine settings files.
Autorun is disabled on this port. No executable files will be accepted by the port.
Modifying the software upgrade, network logging or saved machine settings files will make the files unusable on a WorkCentre .
The data in the network logging file is encrypted and can only be decrypted by Xerox service.
The machine settings that can be saved and restored by a service technician are limited to controller and fax parameters that are needed for normal operation. For example, the fax address book can be saved and restored by a service technician.
There is no method for a user, administrator or technician to move image data from the WorkCentre to a USB device.
USB
USB port and location | Purpose |
|
|
USB Host ports | Software upgrade |
|
|
Ver. 2.00, March 2011 | Page 10 of 50 |