HINTS AND TIPSXEROX FREEFLOW SCANNER 665
Table 2-1. FreeFlow Scanner 665 Hints and Tips
# | Feature/Function | Hints/Tips |
|
|
|
|
|
|
13 | Low resolution | Scanning text printed in 10pt font or less at resolutions of 100 dpi or less |
| scanning of text | will result in image content that may be difficult to discern. These low- |
|
| resolution selections are typically used for generating thumbnails. If better |
|
| readability is desired, resolutions of 200 dpi of higher should be used. |
|
|
|
14 | Original Types / | Originals scanned using incorrect “Original Type” selection (scanning a |
| Image File Sizes | halftone in “Photograph” mode, for example) can yield image file sizes that |
|
| are significantly larger than the resultant file size scanned in the correct |
|
| “Original type”. |
|
|
|
15 | Originals with a large amount of dark content on the reverse side of a page, | |
| through when | may exhibit more |
| scanning from the | scanned through the document feeder. If |
| platen | a black piece of paper on top of the original being scanned from the platen. |
|
| A stronger “background suppression” setting may also help in removing |
|
| unwanted |
|
|
|
16 | Scanner Support | Unpredictable behavior can result if the scanner diagnostic software |
|
| (“Scanner Support” application) is invoked while the scanner is booting. |
|
| The application should be run with the scanner fully powered off, or fully |
|
| powered on. |
|
|
|
17 | Image registration | If scanned images repeatedly contain thin, black lines on the edge of the |
|
| image, run the “Setup Registration” routine in the “Scanner Support” |
|
| application to |
|
|
|
18 | “Help” | The following information in “Help” about “Scan Tickets” is incorrect: |
|
| 1. Within the Twain GUI, go to the Help menu and then the Index |
|
| Scan Tickets. |
|
| 2. Choose the “Backing up your scan ticket tiles” option. |
|
| 3. Part 2 reads: Select [Start: Programs: Windows Explorer] - with |
|
| Windows XP, it should read [Start: Programs: Accessories: Window |
|
| Explorer]. |
|
| 4. Part 3 reads: “Browse to C:\winnt\Twain_32\Xerox665s\international” - |
|
| with Windows XP, it should read “C:\Program Files\Common |
|
| Files\Xerox\Scanner”. |
|
| The following information in “Help” on “Scanner Specifications” is incorrect: |
|
| 1. Within the Twain GUI go to Help |
|
| Reference |
|
| 2. Note that under the Minimum paper dimensions reads 6.5 x 5.5 inches, |
|
| long edge feed — this should read short edge feed. |
|
| 3. Under document Feeder |
|
| Binary B/W reads 76 - 1200 dpi — should read 72, 75, 96, 100, 120, |
|
| 150, 200, 240, 300, 400, 600, 1200 dpi. |
|
|
|
19 | Electronic Page | Although the “Electronic Page Deskew” (Options: Preferences) is enabled |
| Deskew | when scanning from the platen or the feeder, it is only functional when |
|
| scanning from the feeder. |
|
|
|
CUSTOMER SOFTWARE RELEASE SUPPLEMENT |