37
[XG Format]
F0H, 43H, 1nH, 4CH, ahH, amH, alH, ddH, ~, ddH, F7H
1n : n=Device Number
ah : Address High
am : Address Mid
al : Address Low
dd : Data
1) XG System On (receive only) See <Table 1>
2) XG System Parameters See <Table 2>
3) Multi Part Parameters See <Table 3>
When this message is sent, the preset Part Number is used.
[Other]
1) MIDI Master Tune (receive only)
F0H, 43H, 1nH, 27H, 30H, 00H, 00H, mmH, llH, ccH, F7H
1n : n=Device Number
mm : Master Tune MSB
ll : Master Tune LSB
cc : Don’t care
When received, the System Parameter will reflect the Master
Tune.
<BULK DUMP> (receive only)[VL70-m Native Format]
F0H, 43H, 0nH, 57H, bmH, blH, ahH, amH, alH, ddH, ~, ddH,
ccH, F7H
0n : n=Device Number
bm : Byte Count MSB
bl : Byte Count LSB
ah : Address High
am : Address Mid
al : Address Low
dd : Data
cc : Check Sum
1) VL System Parameters See <Table 3>
2)
Current Voice / Common Misc Parameters
See <Table 4>
3)
VL Part Parameters
See <Table 6>
4)
Current Voice / Element Parameters
See <Table 8>
6) Custom Voice Parameters See <Table 9>
7) Internal Voice Parameters See <Table 10>
[XG Format]
F0H, 43H, 0nH, 4CH, bmH, blH, ahH, amH, alH, ddH, ~, ddH,
ccH, F7H
0n : n=Device Number
bm : Byte Count MSB
bl : Byte Count LSB
ah : Address High
am : Address Mid
al : Address Low
dd : Data
cc : Check Sum
1) XG System Parameters See <Table 2>
2) Multi Part Parameters See <Table 5>
For the Address and Byte Count, refer to the supplemen-
tary tables.
Here, the Byte Count is indicated by the “TOTAL SIZE”
in the table.
The block’s leading byte is the Bulk Dump and Dump
Request’s Address.
A “Block” is the lumped together unit which is bound by
the “Total Size”.
The Check Sum is the value that results in a value of 0
for the lower 7 bits when the Address, Byte Count, Data,
plus the Check Sum itself are added.
3)
Part Assign (MIDI Parameter Change)
See <Table 7>
F0H 43H 1nH 4CH 70H nnH ssH ppH F7H
n: Device Number
nn: Plug-in Board Type (PLG100-VL is "00.")
ss: Serial Number (which identifies the PLG boards when two
same boards are installed)
00: for first PLG100-VL
01: for second PLG100-VL
pp: Part Number (to which the PLG100-VL is assigned.)
00: Part 1
.
.
0F: Part 16
7F: off
8. REALTIME MESSAGES<Active Sensing> (receive only)Status :FEH
Once Active Sensing is received, if no MIDI data is received
for longer than an interval of 300msec, the instrument will
perform the same function as when ALL SOUND OFF and
ALL NOTE OFF, RESET ALL CONTROLLER messages are
received, and will return to the status in which Active Sensing
is not monitored.
MIDI Data Format