MIDI data format Add-1
ProR3 Digital Reverberator
MIDI data format

1. Transmitted data

1-1System information

#1 Program bulk data
This data can be transmitted on the currently selected MIDI channel.
This data is transmitted when you select a program in the Utility Bulk Dump display and exe-
cute, or when a Program Bulk Dump Request message is received.
Data will be transmitted for the User program of the specified number.
Also, if the program number is “A11”, data for User programs 1–90 will be transmitted consecu-
tively.
STATUS
ID No.
SUB STATUS
FORMAT No.
BYTE COUNT
BYTE COUNT
DATA NAME
PROGRAM No.
DATA
CHECK SUM
EOX
11110000(F0H)
01000011(43H)
0000nnnn(0nH)
01111110(7EH)
00000010(02H)
01111000(64H)
01001100(4CH)
01001101(4DH)
00100000(20H)
00100000(20H)
00111000(38H)
01000001(41H)
00111000(38H)
00110011(33H)
01001101(4DH)
0mmmmmmm
0ddddddd
0eeeeeee
11110111(F7H)
n=0-15
"L"
"M"
Space
Space
"8"
"A"
"8"
"3"
"M"
m=1-90
Memory bulk (346bytes)
0ddddddd