Recalling the Registered Panel Setups
PSR-3000/1500 Owner’s Manual 133
Registering and Recalling Custom Panel Setups
4Use the [E] button to determine how Registration Sequence behaves
when reaching the end of the sequence (SEQUENCE END).
STOP.....................Pressing the TAB [
®
] button or the “advance” pedal has
no effect. The sequence is “stopped.”
TOP....................... The sequence starts again at the beginning.
NEXT BANK...........The sequence automatically moves to the beginning of
the next Registration Memory Bank in the same folder.
5Program the Sequence order.
The numbers shown at the lower part of the display correspond to the REG-
ISTRATION MEMORY [1]–[8] buttons on the panel.
Program the Sequence order from left to right.
Press one of the REGISTRATION MEMORY [1]–[8] button on the
panel, then press the [6
ππ
ππ
] (INSERT) button to input the number.
• Replacing the number
Press the [5
π†
] (REPLACE) button to replace the number at the cursor
position with the currently selected Registration Memory number.
• Deleting the number
Press the [7
π†
] (DELETE) button to delete the number at the cursor
position.
• Deleting all numbers
Press the [8
π†
] (CLEAR) button to delete all numbers in the sequence.
6Press the [F] button to turn the Registration Sequence function on.
7Press the [EXIT] button to return to the Main display and confirm
whether the Registration Memory numbers are called up according
to the sequence programmed above.
Use the TAB [
®
] button to call up the Registration Memory numbers in the
order of the sequence, or use the TAB [
] button to call them up in
reverse order. The TAB [
]/[
®
] buttons can only be used for Registration
Sequence when the Main display is called up.
When pedal operation has been set in step 3, you can use a pedal to select
the Registration Memory numbers in order. The pedal can be used for Reg-
istration Sequence no matter which display is called up (except for the dis-
play in step 3 above).

Saving the Registration Sequence Settings

The settings for the Sequence order and how Registration Sequence behaves when
reaching the end of the sequence (SEQUENCE END) are included as part of the
Registration Memory Bank file. To store your newly programmed Registration
Sequence, save the current Registration Memory Bank file.
1Press the REGISTRATION MEMORY [REGIST. BANK] button to call up
the REGISTRATION BANK Selection display.
2Press the [6
] button to save the Bank file (page 67).
CAUTION
Settings in the REGISTRATION
SEQUENCE display are auto-
matically saved to the instru-
ment when you exit from this
display. However, if you turn
the power off without exiting
from this display, the settings
will be lost.
Returning to the first
Sequence in one action
In the Main display, press the
TAB [
] and [
®
] buttons simul-
taneously. This cancels the cur-
rently selected Sequence
number (the box indicator at the
top right goes out). The first
Sequence will be selected by
pressing one of the TAB [
]/[
®
]
buttons or by pressing the pedal.
The Registration Sequence is indicated at the top right
of the Main display, letting you confirm the currently
selected number.
CAUTION
Keep in mind that all Registra-
tion Sequence data is lost
when changing Registration
Memory Banks, unless you’ve
saved it with the Registration
Memory Bank file.