AUTO SETUP

Troubleshooting for auto setup procedure

Before auto setup

Error message

Cause

Remedy

 

 

 

Connect MIC!

Optimizer microphone is not connected.

• Connect the supplied optimizer microphone to the

 

 

OPTIMIZER MIC jack on the front panel.

 

 

 

Unplug HP!

Headphones are connected.

• Unplug the headphones.

 

 

 

During auto setup

Press j/ ito display the detailed information about the individual error. Select RETRY to try auto setup procedure again.

Error message

Cause

Remedy

 

 

 

E-1:NO FRONT SP

Front L/R channel signal(s) is (are) not

• Select the front speakers with SPEAKER A or B.

 

detected.

• Check the front L/R speaker connections.

 

 

 

E-2:NO SURR.SP

A surround channel signal is not detected.

• Check the surround speaker connections.

 

 

 

E-3:NO PRES. SP

A presence channel signal is not detected.

• Check the presence speaker connections.

 

 

 

E-4:SBR->SBL

Only right surround back channel signal is

• Connect the surround back speaker to the LEFT

 

detected.

SURROUND BACK SPEAKERS terminal if you

 

 

only have one surround back speaker.

 

 

 

E-5:NOISY

Background noise is too loud.

• Try auto setup procedure in quiet environment.

 

 

• Turn off noisy electric equipment like air conditioners

 

 

(etc.) or move it away from this unit.

 

 

 

E-6:CHECK SURR.

Surround back speaker(s) is (are) connected,

• Connect surround speakers when you use (a)

 

though surround L/R speakers are not.

surround back speaker(s).

 

 

 

E-7:NO MIC

The optimizer microphone was unplugged

• Connect the supplied optimizer microphone to

 

during the auto setup procedure.

OPTIMIZER MIC jack on the front panel.

 

 

 

E-8:NO SIGNAL

The optimizer microphone does not detect test

• Check the microphone setting.

 

tones.

• Check the speaker connections and placement.

 

 

 

E-9:USER CANCEL

The auto setup procedure was cancelled

• Perform the auto setup procedure again.

 

because a setting which affects the auto setup

 

 

was changed during the procedure.

 

 

 

 

After auto setup

Press j/ i to display the detailed information about the individual error.

Warning message

Cause

Remedy

 

 

 

W-1:OUT OF PHASE

Speaker polarity is not correct. This message

• Check the speaker connections.

 

may appear depending on the speakers even

 

 

when the speakers are connected correctly.

 

 

 

 

W-2:OVER 24m

The distance between the speaker and the

• Bring the speaker closer to the listening position.

(80ft)

listening position is over 24 meters (80ft.).

 

 

 

 

 

 

W-3:LEVEL ERROR

The difference of volume level among speakers

• Readjust the speaker installation.

 

is excessive. (No level correction is made.)

• Check the speaker connections.

 

 

• Use speakers of similar quality.

 

 

• Adjust the output volume of the subwoofer.

 

 

 

W-4:SWFR PHASE

The phase polarity of the subwoofer is not

• We recommend that you select the opposite phase on

 

correct.

the subwoofer if the subwoofer has a phase switch.

 

 

 

W-5:VOL ERROR

The result may not be correct because the

• Perform the auto setup procedure again. Do not

 

volume was changed during the auto setup

change the volume during the auto setup procedure.

 

procedure.

 

 

 

 

If the warning message W-2 or W-3 appears on the OSD, no corrections are made. In such cases, correct the problem, select CHECK in DISTANCE or LEVEL, then perform the auto setup procedure again.

If the message W-1, W-4 or W-5 appears on the OSD, corrections are made. However, the corrections may not be correct. In such cases, correct the problem, then perform the auto setup procedure again on the relevant setting items.

PREPARATION

English

27