TROUBLESHOOTING
Problem | Cause | Remedy | Refer |
|
|
| to page |
|
|
|
|
The volume level is low | The record is being played on a turntable | The turntable should be connected to this unit | 16, 17 |
while playing a record. | with an MC cartridge. | through an |
|
|
|
|
|
The volume level | The component connected to the OUT | Turn on the power to the component. | 16 |
cannot be increased, or | (REC) jacks of this unit is turned off. |
|
|
the sound is distorted. |
|
|
|
|
|
|
|
The sound effect | It is not possible to record the sound |
| 41 |
cannot be recorded. | effect by a recording component. |
|
|
|
|
|
|
A source cannot be | A source component is only connected to | Connect the source component to the digital | 15 – 18 |
recorded by a digital | the analog input jacks of this unit. | input jacks of this unit. |
|
recording component |
|
|
|
connected to the |
|
|
|
DIGITAL OUTPUT jack |
|
|
|
of this unit. |
|
|
|
|
|
|
|
The sound field | “14 MEMORY GUARD” on the SET | Select OFF. | 65 |
parameters and some | MENU is set to ON. |
|
|
other settings on this |
|
|
|
unit cannot be |
|
|
|
changed. |
|
|
|
This unit does not | The internal microcomputer has been |
operate properly. | frozen by an external electric shock (such |
| as lightning or excessive static electricity) |
| or by a power supply with low voltage. |
Disconnect the AC power cord from the outlet | — |
and then plug it in again after about 30 seconds. |
|
“CHECK SP WIRES” appears on the front panel display.
Speaker cables are short circuited.
Make sure all speaker cables are connected | 12 |
correctly. |
|
The sound is degraded This unit is in the standby mode.Turn on the power of this unit.20
when listening with headphones connected to a tape deck or CD player that is connected to this unit.
There is noise interference from digital or
This unit is too close to the digital or
Move this unit further away from such | — |
equipment. |
|
This unit suddenly | The internal temperature becomes too |
turns into the standby | high and the overheat protection circuitry |
mode. | has been activated. |
Wait until this unit cools down and then turn it | — |
back on. |
|
78