26
MIDI DATA FORMAT
1. KEY ON / KEY OFF
Status :9nH/8nH
If the Part Parameter Rcv NOTE MESSAGE = OFF, that Part
will ignore Key ON and Key OFF messages.
2. PROGRAM CHANGE
Status :CnH
If the Part Parameter Rcv PROGRAM CHANGE = OFF, that
Part will not receive Program Change Messages.
3. PITCH BEND
Status :EnH
If the Part Parameter Rcv PITCH BEND = OFF, that Part will
not receive Pitch Bend Messages.
4. CONTROL CHANGE
Status :BnH
If the Part Parameter Rcv CONTROL CHANGE = OFF, that
Part will not receive Control Change Messages.
<Bank Select MSB/LSB> 00H/20H
Cntrl#
parameter Data Range
0 Bank Select MSB 33:Preset1/Preset2/Custom/
Internal
81: VL-XG non alternative voice.
97: VL-XG alternative voice.
32 Bank Select LSB 0 :Preset1
1 :Preset2
2 :Custom
3 :Internal
112...119: VL-XG Alternative or
non alternative variation.
If the Part Parameter Rcv BANK SELECT = OFF, that Part
will not receive Bank Select Messages. A new bank selection
will not become effective until the next Program Change is
received.
<Modulation> 01H
Cntrl#
parameter Data Range
1 Modulation 0...127
If the Part Parameter Rcv MODULATION = OFF, that Part
will not receive Modulation Messages.
<Breath Controller> 02H
Cntrl#
parameter Data Range
2 Breath Controller 0...127
<Foot Controller> 04H
Cntrl#
parameter Data Range
4 Foot Controller 0...127
<Portamento Time> 05H
Cntrl#
parameter Data Range
5 Portamento Time 0...127
When the Portamento parameter = ON, values will adjust the
speed of pitch change.
A setting of 0= minimum portamento time, and 127 = maxi-
mum portamento time.
<Data Entry MSB/LSB> 06H/26H
Cntrl#
parameter Data Range
6 Data Entry MSB 0...127
38 Data Entry LSB 0...127
Messages which set the value for the parameter specified by
RPN, NRPN.
<Main Volume> 07H
Cntrl#
parameter Data Range
7 Main Volume 0...127
If the Part Parameter Rcv MAIN VOLUME = OFF, that Part
will not receive Main Volume Messages.
<Pan> 0AH
Cntrl#
parameter Data Range
10 Panpot 0...127
If the Part Parameter Rcv PAN = OFF, that Part will not re-
ceive Pan Pot Messages. 0=Left, 127=Right.
<Expression> 0BH
Cntrl#
parameter Data Range
11 Expression 0...127
If the Part Parameter Rcv EXPRESSION = OFF, that Part will
not receive Expression Messages.
<Control Change 13> 0DH
Cntrl#
parameter Data Range
13 Control Change 13 0...127
<Hold1> 40H
Cntrl#
parameter Data Range
64 Hold1 0...127 (0-63:Off, 64-127:On)
If the Part Parameter Rcv HOLD 1 = OFF, that Part will not
receive Hold 1 Messages.
<Portamento> 41H
Cntrl#
parameter Data Range
65 Portamento 0...127 (0-63:Off, 64-127:On)
If the Part Parameter Rcv PORTAMENTO = OFF, that Part
will not receive Portamento Messages. If the Portamento pa-
rameter = ON, values will adjust the speed of the portamento.
If the Mono mode is activated and Portamento = ON, the Single
Trigger Mode will be activated. If not, the Multi-Trigger Mode
will be effective.