TECHNICAL SPECIFICATION
YEOMAN
Model |
|
| 50 | 60 | 80 | |
|
|
| ||||
Yeoman Devon 50 |
|
| Devon | County | County | |
|
|
|
|
| ||
Yeoman County 60 |
|
| Yeoman | Yeoman | Yeoman | |
Yeoman County 80 |
|
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
Nominal Heat Output to Room | Solid Fuel | kW | 5.0 | 7.0 | 9.0 | |
Nominal Heat Output to Water |
| kW | 8.0 | 11.0 | 14.0 | |
|
|
|
|
|
| |
Flue Draught at Nominal Heat Output | All Fuels | mm Wg | 1.25 | 1.25 | 1.25 | |
|
|
|
| |||
inch Wg | 0.05 | 0.05 | 0.05 | |||
|
| |||||
Flue Outlet Size (Top or Rear option) |
| mm | 150 | 150 | 150 | |
| inch | 6 | 6 | 6 | ||
|
| |||||
Minimum Hearth Type Required | Constructional = CH |
| CH | CH | CH | |
12mm hearth = 12mm |
| |||||
|
|
|
|
| ||
|
|
|
|
|
| |
Weight |
| kg | 135 | 172 | 235 | |
|
|
|
|
|
| |
Recommended Fuels | Solid Fuels | Briquette smokeless fuel suitable for closed appliances. | ||||
(Ancit - Phurnacite - Taybrite - Homefire ovals) | ||||||
|
|
Organisations authorised to certify competence in the installation of domestic solid fuel appliances (Competent Persons Scheme):
APHC - Association of Plumbing and Heating Contractors (Certification) Ltd. www.aphc.co.uk
BESCA - Building Engineering Services Competence Accreditation Ltd.
www.besca.org.uk
HETAS - Heating Equipment Testing and Approval Scheme Ltd.
www.hetas.co.uk
NAPIT - National Association of Professional Inspectors and Testers Ltd.
www.napit.org.uk
NICEIC - NICEIC Group Ltd.
www.niceic.org.uk
HETAS Approved Chimney Sweeps:
Nacs - The National Association of Chimney Sweeps www.chimneyworks.co.uk
APICS - The Association of Master Chimney Sweeps Ltd. www.apics.org
The Guild of Master Chimney Sweeps guildofmasterchimneysweeps.co.uk