REFUELLING

USER INSTRUCTIONS

6

PR8855

7

Airwash: Fully Open

Primary Air: Fully Open

PR7519

Wood burns best on a bed of ash (approx. 25mm (1") deep).

Rake the embers evenly over the firebed and open the Airwash control fully for a few minutes before re-fuelling.

Do not refuel when a large amount of flames are present in the firebox as this could cause smoke or flames to spill into the room.

Close the doors immediately after refuelling.

5.3Burn new logs at a high temperature for a few minutes before adjusting the Airwash control. Refuel little and often for clean, efficient burning.

Do not load above the log guard or base of baffle.

5.4Do not burn large amounts of fuel with the Airwash control closed for long periods of time. This reduces the glass cleaning effect of the Airwash and causes tars and creosotes to build-up in the appliance and flue system.

5.5When in use, running the appliance at a high temperature for a short period reduces tars and creosotes.

5.6Experience establishes settings to suit personal preference.

Do not burn construction timber, painted, impregnated / treated wood, manufactured board products or pallet wood.

BURNING SOLID FUEL

5.7To burn smokeless fuels a cast iron multi-fuel kit must be fitted. Set air controls as shown in Diagram 7.

5.8De-ash the firebed before re-fuelling (see User Instructions, Section 7).

Open the Primary air control fully to establish a glowing bed before adding new fuel.

Burn new fuel at a high temperature (see Diagram 6) for a few minutes before adjusting the Primary air control to the desired setting.

Refuel little and often for clean, efficient burning.

5.9Experience establishes settings to suit personal preference.

5.10Do not burn large amounts of fuel with the Primary air control on a low combustion setting for long periods of time. This reduces the glass cleaning effect of the Airwash and causes tars and creosotes to build-up in the appliance and flue system.

5.11When in use, burning the appliance at a high temperature for a short period reduces tars and creosotes.

5.12Only anthracite or smokeless fuels suitable for use in closed appliances must be burned in this appliance.

5.13Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this invalidates the product guarantee.

5.14Do not load fuel above the log guard and the Secondary Air Inlets at the back of the firebox (see Diagram 5).

REFUELLING

5.15De-ash the fire bed before refuelling, see Ash Removal

Open the Primary air control fully to establish a glowing bed before adding new fuel.

Do not refuel when a large amount of flame is present in the firebox as this could cause smoke or flames to spill into the room.

Close the doors immediately after refuelling.

Burn new fuel at a high temperature for a few minutes before adjusting the Primary air control to the desired setting.

Refuel little and often for clean, efficient burning.

5.16Do not re-fuel the stove above the level of the log guard or the base of the baffle.