Yeoman DEVON 50 manual Installation Instructions, Do not use a 90˚ elbow to make this connection

Models: DEVON 50

1 39
Download 39 pages 9.71 Kb
Page 23
Image 23
Do not use a 90˚ elbow to make this connection.

INSTALLATION INSTRUCTIONS

3

PR8009

The Flue must be installed in accordance with manufacturers instructions.

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

6"

4602

Self tapping screw at rear

Seal flue collar with Fire Cement

PR7196

Connect tee to the chimney using flue pipe.

Secure with self tapping screw.

Seal the connecting joints.

Do not use a 90˚ elbow to make this connection.

The Flue must be installed in accordance with manufacturers instructions.

Seal Collar with Fire Cement

Self Tapping Screw

 

 

Tee

 

Size

Stovax Part No.

 

6"

4616

Cap

PR7218

To chimney connection 1.3Rear flue pipe installation as detailed in building regulations

Elbow with access cover

Size Stovax Part No.

6" 4612

600mm min

To chimney connection Manual background as detailed in building regulations

Elbow with access cover

Size Stovax Part No.

6" 4612

7" 4712

600mm min

1000mm max unsupported

7" 4712

Flue Pipe 915mm (3ft)

Size Stovax Part No.

6" 4602

7" 4702

1000mm max unsupported

Flue Pipe 915mm (3ft)

Size Stovax Part No.

6" 4602

7" 4702

PR7193

PR7195

1.3Rear flue pipe installation

Insert a tee into the flue collar. The tee piece is used as cleaning access.

Lift appliance into position taking care not to damage the hearth finish.

Level using adjustable bolts.

23

Page 23
Image 23
Yeoman DEVON 50 Installation Instructions, Do not use a 90˚ elbow to make this connection, 1.3Rear flue pipe installation