Do not use a 90˚elbow to make this connection.

INSTALLATION INSTRUCTIONS

PR8009

The flue must be installed in accordance with manufacturers instructions.

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

5"

4502

6"

4602

Self tapping screw at rear

Seal flue collar with Fire Cement

—Secure with self tapping screw.

—Seal the connecting joints.

Do not use a 90˚elbow to make this connection.

The flue must be installed in accordance with manufacturers instructions.

Seal Collar with Fire Cement

Self tapping screw

 

 

Tee

 

Size

Stovax Part No.

 

5"

4516

 

6"

4616

 

 

 

Cap

PR8735

To chimney connection 2. REMOVAL OF THE LOG GUARD as detailed in building regulations

PR8733

600mm min

1000mm max unsupported

Elbow with access cover

Size Stovax Part No.

5" 4512

6" 4612

600mm min

1000mm max unsupported

1.3Rear flue pipe installation: To chimney connection as detailed in building regulations

Elbow with access cover

Size

Stovax Part No.

 

 

5"

4512

6"

4612

 

 

Flue Pipe 915mm (3ft)

Size Stovax Part No.

5" 4502

6" 4602

Flue Pipe 915mm (3ft)

Size Stovax Part No.

5" 4502

6"

4602

PR8736

2. REMOVAL OF THE LOG GUARD

2.1 To remove the Log guard:

—Lift Log Guard clear of the supporting brackets.

—Rotate to clear the sides of the door opening.

PR8734

1.3Rear flue pipe installation:

—Insert a tee into the flue collar. The tee piece is used as cleaning access.

—Lift appliance into position, taking care not to damage the hearth finish.

—Level using adjustable bolts.

—Connect tee to the chimney using flue pipe.

Do not use appliance without the log guard in position.

Refer to table on page 17.