INSTALLATION INSTRUCTIONS
7. CAST TOP
This appliance can be fitted with an optional cast top plate. The type of plate will depend on whether the appliance is installed with a top* or rear flue exit.
| Top Flue | Rear Flue |
|
|
|
Yeoman CL3 | ||
|
|
|
Yeoman CL5 | ||
Yeoman CL8 |
*The cast top must be fitted at the same time as the flue connection (see Installation Instructions, Sections 1 & 7).
7.1The cast top plate has 4 silicon feet on the bottom to space it off the top of the appliance by 6mm and allow the door to open freely.
Cast feet |
PR8756 |
7.2Place the cast top plate feet down on top of the appliance.
Line up edges |
of cast top |
plate with the |
appliance |
PR8744 |
8. co alarms
All open flued appliances can be affected by temporary atmospheric conditions which may allow fumes to enter the house. Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the installation of the carbon monoxide alarm is available in the latest edition of
BS EN50292 and from the alarm manufacturer's instructions.
Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system.