PRE-INSTALLATION CHECKS

PRE-INSTALLATION CHECKS

1. Flue

Model

 

 

CL3

CL5

CL8

Yeoman CL3 - YM-CL3MF

 

 

 

 

Yeoman

Yeoman

Yeoman

Yeoman CL5 - YM-CL5W / YM-CL5MF

 

 

 

 

 

Yeoman CL8 - YM-CL8W / YM-CL8MF

 

 

 

 

 

 

 

 

 

 

 

Without Liner System

mm

150

150

150

 

 

 

 

 

 

Round (diameter)

inch

6

6

6

 

 

 

 

 

 

 

 

Flue / Chimney Size

Without Liner System (square)

mm

135

135

135

Minimum Dimension

inch

 

 

 

 

With Liner or Factory Made

mm

‡150

150

150

 

System (diameter)

mm

‡6

6

6

 

 

 

 

 

 

 

 

Flue / Chimney

 

m

4

4

4

 

 

 

 

 

minimum height*

 

feet

13

13

13

 

 

*When measured from the top of the flue, with no horizontal sections and a maximum of 4 bends with angles of less than 45°

‡May be 125mm (5") if burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas.

See web site http://uksmokecontrolareas.co.uk for more information about approved fuels.

2. VENTILATION

2.1This appliance requires a constant supply of air to maintain proper combustion and effective flue performance.

2.2An inadequate air supply can result in poor combustion and smoke entering the room which is potentially dangerous.

2.3This supply of air can come from either:

The natural leakage of air into the room in which the product is fitted.

Purpose provided ventilation.

Some Stovax appliances can also be fitted with an optional outdoor air kit which allows air to be drawn in from the outside.

2.4The amount of air required must comply with local building regulations and the rules in force.

2.5If spillage is detected during commissioning then there may be insufficient natural ventilation and an additional air supply will be necessary.

2.6Many older buildings are sufficiently ventilated by natural leakage of air to provide suitable air supply for an appliance of 5kW output or less.

Modern building techniques have reduced the amount of air that leaks in or out of a house. A modern construction with an air tightness of less than 5m3 per hour per m2 requires an air vent for ALL solid fuel appliances including those with a rated heat output of less than 5kW.

NOTE: The air leakage of a modern house is tested at the completion of construction and a certificate issued confirming this.

17