Yeoman YM-CL5MF, YM-CL8W, YM-CL5W User Instructions, General POINTS, Serial Number, Air Controls

Models: YM-CL5W YM-CL5MF YM-CL8W YM-CL8MF YM-CL3MF

1 34
Download 34 pages 10.5 Kb
Page 4
Image 4
USER INSTRUCTIONS

USER INSTRUCTIONS

1.General POINTS

1.1Before use of this appliance please read these instructions fully.

The appliance must be fitted by a registered installer*, or approved by your local building control officer.

1.2All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.

1.3Only use for domestic heating in accordance with these operating instructions.

1.4You must burn only approved fuels. Do not use with liquid fuels or as an incinerator.

1.5Appliance surfaces become very hot when in use. Use a suitable fireguard if young children, elderly or infirm persons are present.

Stovax offer firescreens, sparkguards and hearthgate systems for protection. Your Yeoman retailer can advise you about these products.

1.6Do not place photographs, TV’s, paintings, porcelain or other combustible items on the wall or near the appliance. Exposure to hot temperatures will cause damage.

1.7Extractor fans or cooker hoods must not be placed in the same room or space as this can cause appliance to emit fumes into the room.

1.8Do not obstruct inside or outside ventilation required for the safe use of this appliance.

1.9Do not make unauthorised changes to the appliance.

1.10The chimney must be swept at least once a year (see User Instructions, Section 13).

1.11Do not connect, or share, the same flue or chimney system with another appliance.

1.12This appliance is designed to be used with the doors shut.

SERIAL NUMBER

1.13This number is required when ordering spare parts or making warranty claims. It is found on the appliance data plate.

‡In the U.K. these products must conform to the latest edition of BS 8423, Fireguards for use with solid fuel appliances.

If appliance is operating unattended they must conform to the latest edition of BS 3248.

*Registered on the Competent Persons Scheme (GB only) see page 26 / INFO (Republic of Ireland).

Data Plate

PR8745

The data plate is found on a swing out data plate located on the back of the stove on the left hand side (see Diagram 1).

AIR CONTROLS

Triple Air Systems

This Yeoman appliance has a triple air system, providing cleaner burning and greater efficiency and control (see Diagram 2).

1)Airwash - air drawn over the window cleans the glass. The source of Primary Combustion air when burning wood.

2)Primary Air - for use with solid fuel and when lighting wood fires.

3)Cleanburn - secondary air is preheated through a heat exchanger to combust unburned hydrocarbons, providing a cleaner and more efficient burn.

PR8702

For Air Controls see the diagram over.

Use the tool provided to operate the air controls.

Do not place tool on hot surfaces (e.g. top of stove).

4

Page 4
Image 4
Yeoman YM-CL5MF, YM-CL8W, YM-CL5W, YM-CL8MF, YM-CL3MF manual User Instructions, General POINTS, Serial Number, Air Controls