York B2CH180 Table Of Contents, Installation, Operation, Maintenance, Tables, Figures

Models: B2CH180

1 16
Download 16 pages 30.24 Kb
Page 2
Image 2
TABLE OF CONTENTS

035-18895-000-A-0902

TABLE OF CONTENTS

General

1

Inspection

1

Reference

1

Nomenclature

2

INSTALLATION

 

Limitations

3

Location

3

Rigging and Handling

3

Clearances

3

Ductwork

3

Fixed Outdoor Air Intake Damper

4

Condensate Drain

4

Compressors

4

Filters

4

Service Access

4

Thermostat

4

Power and Control Wiring

5

Optional Electric Heaters

5

Optional Econ./Motorized Damper Rain Hood

6

OPERATION

 

Cooling System

12

Preliminary Operation

12

Cooling Sequence of Operation

12

Heating Sequence of Operation

12

Heat Anticipator Setpoint

13

Checking Supply Airflow

13

Defrost Sequence of Operation

14

Secure Owner's Approval

15

 

MAINTENANCE

 

Normal Maintenance

15

 

TABLES

 

No.

Description

Page

1

Unit Application Data

3

2

Electric Heat Application Data

5

3

Physical Data

7

4

Supply Air Blower Performance

10

5

Static Resistances

11

6

Blower Motor and Drive Data

11

7

Electrical Data (Basic Units)

11

8

Electrical Data (Units w/Elec. Heat)

11

9

Heat Anticipator Setpoints

13

10

Blower Motor Pulley Adjustment

13

 

FIGURES

 

No.

Description

Page

1

Typical Rigging

3

2

Center of Gravity

3

3

Fixed Outdoor Air Damper

4

4

Recommended Drain Piping

4

5

Typical Field Wiring

5

6

Enthalpy Setpoint Adjustment

7

7

Dimensions and Clearances

8

8

Belt Adjustment

13

9

Pressure Drop versus Supply Airflow

13

10

Defrost Initiation Times

14

11

Ambient Modified Time/Temp. Control

15

B

PRODUCT CATEGORY

B = Single Package Heat Pump (Air Cooled)

PRODUCT GENERATION

2 = 2nd Generation

PRODUCT IDENTIFIER

CH = Heat Pump

PRODUCT NOMENCLATURE

1 INSTALLATIONOPERATION C MAINTENANCE H TABLESFIGURES 1 Manual background 8 Manual background 0 Manual backgroundManual background E Manual backgroundManual background 0 Manual background 3 Manual background 6 Manual backgroundManual background 5 Manual background 0

 

 

 

 

 

VOLTAGE CODE

 

 

 

 

 

 

 

 

 

 

 

 

50 = 400/415-3+N-50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL

 

NOMINAL COOLING

 

 

 

HEATING CAPACITY

 

 

FACTORY INSTALLED

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

018 = 18 kW

 

 

 

 

180 = 49.5 kW (169 MBH)

 

 

 

036 = 36 kW

 

 

A = No Heat

 

 

 

054 = 54 kW

 

 

 

E = Electric Heat

 

 

 

 

 

072 = 72 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Unitary Products Group

Page 2
Image 2
York B2CH180 installation instructions Table Of Contents, Installation, Operation, Maintenance, Tables, Figures

FAQ

What is the voltage code for York B2CH180 heat pump?

The voltage code for York B2CH180 heat pump is 50 = 400/415-3+N-50.

What is the nominal cooling capacity of York B2CH180 heat pump?

The nominal cooling capacity of York B2CH180 heat pump is 180 = 49.5 kW 169 MBH.

Does the York B2CH180 heat pump come with factory installed heating capacity?

Yes, the factory installed heating capacity options for York B2CH180 heat pump are 018 = 18 kW, 036 = 36 kW, 054 = 54 kW, 072 = 72 kW.