FIG. 6 - ENTHALPY SETPOINT ADJUSTMENT
TABLE 3 - PHYSICAL DATA
COMPONENT DESCRIPTION | UNIT SIZE | |
180 | ||
|
WEIGHTS (kg. / lbs.)
BASIC
CENTRIFUGAL BLOWER | DIA. x WD. (mm) | 381 x 381 |
UNIT
180 948 / 2091
SUPPLY AIR |
| DIA. x WD. (in.) | 15 x 15 | |
BLOWER |
| |||
FAN MOTOR | kW / HP | 3.0 / 4 | ||
| ||||
INDOOR | ROWS DEEP |
| 4 | |
FINS PER INCH |
| 13 | ||
COIL |
| |||
FACE AREA | m2 / Ft.2 | 1.45 / 15.5 | ||
| ||||
OUTDOOR | PROPELLER DIA. | mm / in. | 762 / 30 ea. | |
FAN MOTOR | kW / HP | 0.7 / 1 ea. | ||
FANS | ||||
NOMINAL AIRFLOW | m3/s | 2.83 ea. | ||
(Two Per Unit) |
|
| ||
CFM | 6000 | |||
|
| |||
OUTDOOR | ROWS DEEP |
| 3 | |
FINS PER INCH |
| 15 | ||
COIL |
| |||
FACE AREA | m2 / Ft.2 | 3.35 / 36.0 | ||
| ||||
COMPRESSOR | SCROLL (6.5 TON NOMINAL CAPACITY) | 2 | ||
(Qty. Per Unit) | ||||
|
|
| ||
AIR | QUANTITY PER UNIT | 457 x 610 x 51 (mm) | 5 | |
FILTERS | 18 x 24 x 2 (in.) | |||
|
| |||
(SEE NOTE) | TOTAL FACE AREA | m2 / Ft.2 | 1.40 / 15.0 | |
CHARGE | REFRIGERANT 22 | SYS. #1 (kg. / lbs.) | 9.5 / 21.0 | |
SYS. #2 (kg. / lbs.) | 9.5 / 21.0 | |||
|
|
NOTE: Filter racks are adapted to accept 25mm (1") or 51mm (2") filters.
OPTIONS
Economizer |
|
| 73 / 160 | |
Motorized Damper |
| 68 / 150 | ||
|
| 18 kW |
| 11 / 25 |
Electric |
| 36kW |
| 14 / 30 |
Heater |
| 54 kW |
| 16 / 35 |
|
| 72 kW |
| 18 / 40 |
ACCESSORIES |
| |||
Roof Curb |
| 180 |
| 79 / 175 |
Barometric Damper |
| 20 / 45 | ||
Wood |
| 180 |
| 91 / 200 |
Skid* |
|
| ||
|
|
|
|
*Allows handling of unit using 2286mm (90") long forks.
Unitary Products Group | 7 |